FALCON DR  / FALCON XL-DR
 
USER’S GUIDE
 
 
MOTION SENSORS FOR INDUSTRIAL DOORS 
FALCON DR: double relay / high mount  
  FALCON XL-DR: double relay / low mount 
 
Technology                     
:  Microwave and 
microprocessor 
Transmitter frequency    
:  24.125 GHz 
Transmitter radiated power  :  <20 dBm EIRP 
Transmitter power density 
:  < 5 mW/cm² 
Mounting height   
   
• FALCON DR 
:  from 11.5’ (3.5m) to 23’ (7m)  
• FALCON XL-DR 
:  from 6.5’ (2m) to 11.5’ (3.5m) 
Tilt angles 
:  0° to 180° in elevation 
Detection zone 
• FALCON DR 
(mounting height of 5m) 
 
13’ (W) x 16’ (D) 
4m (W) x 5m (D) 
• FALCON XL-DR 
(mounting height of 2.5m) 
 
13’ (W) x 6.5’ (D) 
4m (W) x 2m (D) 
Detection mode 
:  Motion 
Minimum speed 
:  2 in (5cm)/s (measured in the 
sensor axis) 
Supply voltage 
:  12V to 24V AC ±10% 
12V to 24V DC +30% / -10% 
Mains frequency 
:  50 to 60 Hz 
Power consumption 
:  < 2W (VA) 
Two Output relay (free of potential change-over contact) 
• Max. contact voltage 
:  42V AC 
• Max. contact current 
:  1A (resistive) 
• Max. switching power 
:  30W (DC) / 60VA (AC) 
 
Hold time 
0.5s to 9s (adjustable) 
Temperature range 
-22°F to +122°F (-30°C to +60°C) 
Degree of protection 
IP65 
Norm conformity 
R&TTE 1999/5/EC 
EMC 89/336/EEC 
Dimensions : 
4” (W) x 5” (D) x 3 ¾” (H) 
 
  102 mm (W) x 127 mm (D) x 96 mm (H) 
Weight : 
0.88 lbs (0.4 kg) 
Material of housing 
ABS and polycarbonate 
Material of bracket 
Anodized aluminium 
Length of cable 
33’ (10m) 
Manual adjustment 
   
• Orientation of sensing field  (mechanically) 
• Multiple functions (by push buttons) 
Remote control adjustments 
• Sensitivity 
• Hold time 
• Detection mode 
• Pedestrian and parallel traffic rejection mode 
• Output configuration 
• Security 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The sensor must be firmly 
fastened to prevent from 
vibrating.
 
The sensor must not be placed 
directly behind a panel or any kind 
of material.
 
The sensor must not have 
any object likely to move or 
vibrate in its sensing field.
 
The sensor must not have any 
fluorescent lighting in its 
sensing field. 
 
DESCRIPTION OF 
THE SENSOR   
 
INSTALLATION 
TIPS
  
 
 
TECHNICAL 
SPECIFICATION 
Tranceiver module 
(planar antenna) 
 
Green LED 
 
Infrared Receiver 
 
Red LED 
 
 
 
 
 
2 Push Buttons 
 
 
Microprocessor 
 
 
Terminal block