OPD EQUIPPED CYLINDER 
HOSE & REGULATOR 
OVERFILL PREVENTION DEVICE 
The standard for outdoor gas appliances, ANSI 
Z21.58/CAN/CGA-1.6, requires that appliances are to be 
used with cylinders equipped with an Overfill Prevention 
Device (OPD). 
The OPD is designed to reduce the potential for the 
overfilling of propane cylinders, thus reducing the possibility 
of relief valve discharges of raw propane. The OPD 
causes a slower purge/fill operation.
 Some consumers 
have been advised by filling stations that these cylinders 
are “defective”. This is not a defect. Some propane filling 
stations may not be aware of this device and its effect on 
the purge/fill operation. 
New OPDs coming onto the market have technology that 
allows for much greater BTU outputs which will decrease 
the amount of time it takes to purge a cylinder. 
Identification 
To identify these cylinders, the OPD handwheel has been 
standardized to the shape shown. 
 
 
 
 
 
 
 
All models are equipped with a hose and regulator with a  
QCC
®
-1 Quick Closing Coupling. 
1. 
The QCC
®
 coupling contains a magnetic Flow Limiting  
Device which will limit the flow of gas should there be a  
leak between the regulator and the appliance valve. This 
device will activate if the cylinder valve is opened while the 
appliance valves are open. Be sure the appliance  
valves are off before the cylinder valve is opened to 
prevent accidental activation.
   
2. 
The QCC
®
 coupling incorporates a heat sensitive hand wheel 
that will cause the back check module in the QCC
®
 cylinder 
valve to close when exposed to temperatures between 240° 
and 300°F.  Should this occur, do not attempt to reconnect 
the hand wheel. Remove hose/regulator assembly and 
replace with a new one.
 
3. 
The pressure regulator is set at 11 inches WC (water column) 
and is for use with LP gas only.  The hose and hose couplings 
comply with CGA Standard CAN 1.83.  No modifications or 
substitutions should be attempted.
 
4. 
Protect the hose from dripping grease and do not allow the 
hose to touch any hot surface, including the base casting 
of the barbecue.
 
5. 
Inspect the seal in the QCC
®
 cylinder valve when replacing 
the LP gas cylinder or once per year whichever is more 
frequent.  Replace the seal if there is any indication of cracks, 
creases, or abrasion.
 
6. 
Inspect the hose before each use of the barbecue. If the hose 
is cracked, cut, abraded or damaged in any way, the 
appliance must not be operated. 
7. 
For repair or replacement of the hose/regulator assembly, 
contact customer service at 1-800-265-2150 or 
info@omcbbq.com 
Connection 
1. 
Be sure cylinder valve and appliance valves are "off".
 
                    NIPPLE WITH FLOW                                              SHUT OFF VALVE 
                    LIMITING DEVICE 
                                                                                                                  
                HEAT SENSITIVE                                                          CYLINDER                     
                HAND WHEEL 
               
                                                                               
 
            
 
                       REGULATOR 
                                                                                     CHECK VALVE 
2. 
Place full LP gas cylinder in LP tank well and secure base as 
per assembly instructions.
 
3. 
Center the nipple in the cylinder valve and hold in place.  
Using other hand, turn the hand wheel clockwise until there 
is a positive stop. Do not use tools.  Hand tighten only.  
When making the connection, hold the regulator in a 
straight line with the cylinder valve, so as not to cross 
thread the connection. 
4. 
Leak test connections.  See "Leak Testing".
 
5. 
Refer to lighting instructions. To avoid activating the Flow 
Limiting Device when lighting,
 open cylinder valve slowly 
with the appliance valves off.
  If the Flow Limiting Device is 
accidentally activated, turn off cylinder valve and appliance 
valves, wait 10 seconds to allow the device to reset, open 
cylinder valve slowly, then open the appliance valve.