DS62-Network, DS62-MD4 Network/Modem Host Module 
20 
 
 
Serial Port Device Name 
Select a port and type the new name. 
 
 
Attention Character 
Pressing the Attention Character 5 consecutive times will access the network main menu. The Default 
is a semi-colon (;)
. Select this option to change the attention character. The DS displays the following: 
 
 
Disconnect Timeguard 
This feature ensures reliable binary data transmission by providing a one-second “Timeguard” after the 
DS-Series receives the attention character.  If more data is received within the delay period, the DS 
treats the character as data, not an attention character; thereby preventing unwanted port disconnection.  
The Default setting is Disabled. 
 
 
Connect Port ID Echo 
When a user logs into the DS unit the port is identified in the following example: 
 
 
 
Select option 1, to disable the echo. The Default setting is Disabled
Select option 2 to echo the module and port number. (i.e. 3, 2) 
Select option 3 to echo the device name. (Device A) 
 
DTR Line Driver Inactive State is: High
High ? (Y/N, CR for no change): 
Current device name: EIA-RS232
Enter device name for serial port ((1 - 16 char., CR to end) : 
  Attention Character is...........  ; 
 
  Enter Attention Character : 
Disconnect Time Guard is.......... Disabled
Enable ? (Y/N), CR for no change) : 
        BAYTECH 
 
For further information check: 
http://www.baytech.net/ 
 
DS62 
 
   <= 
Device name Port echo. 
  or 
02,1 
   <= 
Module and Port Number echo.