Bay Technical Associates BayTech DS62 用户手册

下载
页码 53
DS62-Network, DS62-MD4 Network/Modem Host Module 
44 
 
 
Select “Parity” the DS displays the following: Default is None. 
 
 
Rings to Auto Answer 
Select “Rings to Auto Answer” to set the number of rings before the unit answers. The module 
displays the following: The default setting is 2
 
  
 
Modem Connectivity Timeout 
Select the Modem Connectivity Timeout option to set the continuous connectivity time (1 to 120 
minutes) before the modem automatically disconnects.  Entering a time of 0 disables the Connectivity 
Timeout.  The timer starts when the modem answers (DCD goes high).  The modem will disconnect, 
regardless of activity, when time runs out.  Default setting is 60 minutes. The module displays the 
following: 
 
  
 
Modem Inactivity Timeout 
This option sets the time the modem will automatically disconnect, if there is no activity equaling the 
programmed amount of time (1 to 120 minutes).  Default setting is 0 (disabled)
Select Modem Inactivity Timeout and the module display the following: 
 
  
 
 
Modem Device Name 
Select Modem Device Name and the following is displayed: 
 
Select stop bits: 
  1 For    1 
  2 For    2 
  Enter Request : 
Select parity: 
  1 For  None 
  2 For  Even 
  3 For   Odd 
  Enter Request : 
Rings to Auto Answer: 2 
Enter number (1-4): 
Modem Connectivity Timeout (Minutes): 60 
Enter Timeout (1-120 minutes, 0 to disable): 
Modem Inactivity Timeout (Minutes): 60 
Enter Timeout (1-120 minutes, 0 to disable):