Baracoda RS232 用户手册

下载
页码 9
 
Baracoda KEmul RS232 for PC – User Guide v3.36.3 
  - 7 - 
Data Capture 
for Workforce 
in Motion 
The RS232 Kemul is preset to default settings that  reflect typical serial applications.  These  settings should be 
modified to fit the current application parameters. 
1.
 
COM Port  
 
The COM Port is the communication port that the RS232 dongle is attached to on the host computer. 
The default serial port on a computer is usually COM Port 1. If the serial port on the user’s PC is not  
COM  Port  1,  they  will  need  to  change  this  setting  of  the  RS232  KEmul  program  to  match  the  serial 
COM Port the RS232 dongle is attached to.  
 
2.
 
Baud Rate 
 
The  baud  rate  is  the  data  transmission  rate  of  the  serial  port.  The  RS232  dongle  has  a  default  baud 
rate of 9600 bits/s. The baud rate of the RS232 KEmul has to match the baud rate of the RS232 dongle.  
 
3.
 
Parity 
 
Parity is an error checking algorithm that counts the number of “ones” during data transmission. Even 
parity means there is an even number of “ones” in the data transfer. Odd parity means there is an odd 
number of “ones” in the data transfer. The default value is none because the RS232 dongle is capable 
of transferring data without checking the parity of the data transfer.  
 
4.
 
Data Bits 
 
The data bits specify the size of the data transfer sent by the RS232 dongle. The only selection for this 
option is 8 because the RS232 dongle can only transfer 8 bits of data at a time. 
 
5.
 
Stop Bits 
 
The stop bits are bits that indicate the data transfer is over. The default is one stop bit. However the 
RS232 dongle can be programmed to send 2 stop bits if necessary.