Whirlpool ACQ062MP0 用户手册

下载
页码 24
4
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed. 
Proper installation is your responsibility. Make sure you have 
everything necessary for correct installation.
The location should provide:
Grounded electrical outlet within 4 ft (122 cm) of where the 
power cord exits the air conditioner. 
NOTE: Do not use an extension cord.
Free movement of air to rooms to be cooled.
A large enough opening for the air conditioner. Installation 
parts are supplied for double-hung windows.
Adequate wall support for weight of air conditioner. Air 
conditioner weighs approximately 80 lbs (36 kg).
NOTE: Do not install the air conditioner in an area where the front 
panel will be exposed to heat sources that will raise the panel 
surface temperature above 120°F (50°C).  
Window installation
Window opening measurements:
25 in. (63.5 cm) minimum to 38 in. (96.5 cm) maximum 
opening width
16 in. (40.6 cm) minimum opening height     
Electrical Requirements
In the U.S. only: If codes permit and a separate ground wire is 
used, it is recommended that a qualified electrician determine 
that the ground path is adequate.
Check with a qualified electrician if you are not sure air 
conditioner is grounded.
A three-wire, single-phase, 60-Hz, AC-only, electrical supply is 
required on a separate circuit. A 15-amp time-delay fuse or 
circuit breaker is required. Copper wire (14 gauge) is required. 
The fuse size must not exceed the circuit rating specified on the 
model and serial number label. The model and serial number 
label is located on the left side of the cabinet.
Specific electrical requirements are listed in the chart. Follow the 
requirements for the type of plug on the power supply cord.
Recommended ground method
For your personal safety, this air conditioner must be grounded. 
This air conditioner is equipped with a power supply cord having 
a grounded 3 prong plug. To minimize possible shock hazard, the 
cord must be plugged into a mating, grounded 3 prong outlet, 
grounded in accordance with all local codes and ordinances. If a 
mating outlet is not available, it is the customer's responsibility to 
have a properly grounded 3 prong outlet installed by a licensed 
installer.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 70 -  
latest edition, and all local codes and ordinances.
A. 25 in. (63.5 cm) minimum
B. 16 in. (40.6 cm) minimum
A
B
Power supply cord 
plug outlet
Wiring requirements
115 volt (103.5 min. - 
126.5 max.)
0-12 amperes
15-amp time-delay fuse or 
circuit breaker
14 gauge copper wiring
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Do not use an extension cord.
Do not use an adapter.
Do not remove ground prong.