Laundry tub drain system (view C)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top 
of the laundry tub must be at least 34" (864 mm) above the floor 
and no higher than 96" (2.4 m) from the bottom of the washer.
Floor drain system (view D)
The floor drain system requires a siphon break that may be 
purchased separately. See “Alternate Parts.”
The siphon break must be a minimum of 28" (711 mm) from the 
bottom of the washer. Additional hoses might be needed.
ElectricalRequirements
A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical 
supply is required. A time-delay fuse or circuit breaker is 
recommended. It is also recommended that a separate circuit 
serving only this appliance be provided.
To minimize possible shock hazard, the cord must be plugged 
into a mating, 3 prong, grounding-type outlet, grounded in 
accordance with local codes and ordinances. If a mating 
outlet is not available, it is the personal responsibility and 
obligation of the customer to have the properly grounded 
outlet installed by a qualified electrician.
IMPORTANT: The washer/dryer must be electrically grounded 
in accordance with local codes, or in the absence of local 
codes, with the National Electrical Code, ANSI/NFPA 70 or 
with the Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure the 
washer/dryer is properly grounded. 
Do not have a fuse in the neutral or ground circuit.
GasSupplyRequirements
Gas type
Natural Gas:
This washer/dryer is equipped for use with Natural gas. It is 
design-certified by CSA International for LP (propane or butane) 
gases with appropriate conversion.
Your washer/dryer must have the correct burner for the type of 
gas in your home. Burner information is located on the rating 
plate in the door well of your dryer. If this information does not 
agree with the type of gas available, contact your dealer or call 
the phone numbers referenced on the front page of the 
Washer/Dryer User Instructions.
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting your gas company.
D
C
34"
(864 mm)
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
    For a grounded, cord-connected washer/dryer:
This washer/dryer must be grounded. In the event of 
malfunction or breakdown, grounding will reduce the risk of 
electric shock by providing a path of least resistance for 
electric current. This washer/dryer is equipped with a cord 
having an equipment-grounding conductor and a grounding 
plug. The plug must be plugged into an appropriate outlet 
that is properly installed and grounded in accordance with 
all local codes and ordinances.
WARNING:
 Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or 
personnel if you are in doubt as to whether the washer/dryer 
is properly grounded. Do not modify the plug provided with 
the washer/dryer: if it will not fit the outlet, have a proper 
outlet installed by a qualified electrician.
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS