ELECTRICAL REQUIREMENTS
A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit  
are recommended. 
 
   
 
GAS SUPPLY REQUIREMENTS
Gas supply
This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When 
acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger 
tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed 
within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1. 
 
INSTALLATION REQUIREMENTS
Installation clearances:
The location must be large enough to allow the dryer door to 
open fully.
Most installations require a minimum 5½" (140 mm) clearance 
behind the dryer for the exhaust vent with elbow. See “Venting 
Requirements.”
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
 
Additional spacing should be considered for ease of installation 
and servicing.
 
Additional clearances might be required for wall, door, and floor 
moldings.
 
Additional spacing of 1" (25 mm) on all sides of the dryer is 
recommended to reduce noise transfer.
 
For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilation openings are 
acceptable.
 
Companion appliance spacing should also be considered.