MAINTENANCE
Adding Engine Oil
1.  Always operate or maintain the generator on a flat 
surface.
2.  Stop engine if running.
3.  Let engine sit and cool for several minutes (allow 
crankcase pressure to equalize).
4.  Thoroughly clean around the oil fill plug/dipstick.
5.  Remove oil fill plug/dipstick and wipe clean. 
6.  Select the proper engine oil as specified in Figure 
23.
7.  Using the supplied funnel and tube, slowly add 
engine oil to the engine. Stop frequently to check 
the level to avoid overfilling (see Figure 28).
Figure 28 – Adding Engine Oil
8.  Continue to add oil until the oil is at the correct 
level. See Checking Engine Oil on page 26.
Changing Engine Oil
1.  Stop the engine. 
2.  Let engine sit and cool for several minutes (allow 
crankcase pressure to equalize).
3.  Place oil pan (or suitable container) under the oil 
drain plug.
4.  With a damp rag, thoroughly clean around the oil 
drain plug.
5.  Remove the oil drain plug (see Figure 29). Once 
removed, place the oil drain plug on a clean 
surface.
Figure 29 – Oil Drain Plug
6.  Remove the oil fill plug so the oil can drain more 
easily from the oil drain port.
7.  Allow oil to completely drain.
8.  Replace oil drain plug.
9.  Fill crankcase with oil following the steps outlined in 
Adding Engine Oil on page 27.
NOTICE
Never dispose of used engine oil by dumping the 
oil into a sewer, on the ground, or into groundwater 
or waterways. Always be environmentally 
responsible. Follow the guidelines of the EPA or 
other governmental agencies for proper disposal 
of hazardous materials. Consult local authorities or 
reclamation facility. 
10.  Dispose of used engine oil properly.
AIR FILTER MAINTENANCE
!
 WARNING
Never use gasoline or other flammable 
solvents to clean the air filter. Use only 
household detergent soap to clean the 
air filter. 
Cleaning the Air Filter
The air filter must be cleaned after every 50 hours of 
use or 3 months (frequency should be increased if 
generator is operated in a dusty environment).
1.  Turn off the generator and let it cool for several 
minutes if running.