XI.  
Problem
Cause
Remedy
Taste/Odor  (general)
The carbon block filter may become saturated w ith 
the taste and odors it adsorbs.
Change the filter
Rotten egg odor
Typically a sign of H2S (hydrogen sulfide) gas 
w hich can occur at any time.  
It is recommended that you keep tw o filter cartridges 
on hand.  When one becomes saturated w ith odor, 
remove it and allow  it to dry upside (threaded-hole) 
dow n on a paper tow el.  The sulfur gas w ill dissipate, 
allow ing the cartridge to be reused.  Rotating 
cartridges in this manner w ill, in some cases, help 
extend the life of the filter.
Odor & odd color on cartridge   
H2S (hydrogen sulfide) caused by iron 
(orange/brow nish), manganese (blackish), and/or 
decaying organisms (slimy/blotchy colors) can 
cause rotten egg-type odor.
Change of filter cartridge is the only recommended 
course of action.
“Milky” color in w ater
Higher than normal w ater pressure through the 
System w ill create small bubbles.  Air bubbles do 
not effect the performance of the system.  Air can 
be trapped inside the lid of the housing.  
For a countertop installation, turn on the w ater and 
engage the diverter valve w hile reducing the w ater 
flow  slightly.  For a below  the sink installation, adjust 
the w ater pressure at the feedw ater adapter below  
the sink.  Turn on the ledge faucet or diverter valve 
and let w ater run for 3 to 5 minutes after installation or 
filter change.
Flow  rate is slow
Solids:  The filter is designed to become restricted 
in its flow  rate w hen the filter becomes clogged 
w ith particulate and other contaminants.  When 
your w ater flow  rate slow s to the point that it is 
inconvenient to use, it is time to change your filter.
It is recommended that filters be replaced at least 
every tw elve months or w hen its capacity is reached, 
w hichever comes first.  If w ater pressure is too low , 
adjust w ater pressure to 60 psi.  If other faucets or 
sprinklers are on turn off other running w ater.
Water dripping from faucet assembly
Adjustment of w ater flow  is needed.
Below  sink units - remove the faucet handle by first 
removing the spout (pull straight up) and then slide the 
handle off the faucet base.  Then  turn the small  t-bar 
about one half turn to tighten the faucet assembly.
Water is black
Carbon dust
Allow  w ater to run through the unit to w aste for 
approximately 20 minutes to flush the filter and charge 
the carbon.