Utica Boilers H2OI Dual 安装指导

下载
页码 24
5
BOTTOM SOLAR
COIL RETURN
TOP COIL
SUPPLY
BOTTOM SOLAR 
COIL SUPPLY
T+P VALVE
TOP COIL
RETURN
COLD 
WATER IN
HOT WATER
OUT
BOTTOM HEATING COIL
FOR SOLAR
BOTTOM COIL
3/8" ID THERMAL WELL
TOP HEATING COIL
FOR BACKUP
TOP COIL
3/8" ID THERMAL WELL
DUAL COIL UNITS
1/2" NPT RECIRC.
RETURN PORT
DRAIN VALVE
3/8" ID
THERMAL WELL
4" X 10"
ELECTRICAL BOX
TYPICAL ALL
ELECTRIC BACKUP UNITS
1.5
  Heat exchanger coil outputs
 
Model 
Max. Recovery 
Max. Recovery 
Water Flow 
Pressure Drop
 
 
(gal/hr.) 
(gal/hr.) 
Through Coil 
Through Coil
 
 
Top Coil 
Bottom Coil 
(gal./min.) 
(Ft. Water)
 
115 Gal. Units 
190 
214 
10.0 
3.9
 
80 Gal. Units 
180 
214 
10.0 
3.6
 
60 Gal. Units 
185 
214 
10.0 
3.5 
  Note: All Ratings are based on 180 degree F boiler water supply and 50 degree F cold Water inlet.
  In the interest of continuous improvement, specifications are subject to change without notice.
  
For all units with 3500 watt Electric Backup
 
Model                                         First Hour Rating (gal/hr.)     Continuous Rating (gal/hr.)
 
 
140 F 
115 F 
140 F 
115 F
 
115 Gal. Units 
73.9 
80.0 
15.9 
22.0
 
80 Gal. Units 
55.9 
62.0 
15.9 
22.0
 
60 Gal. Units 
45.9 
52.0 
15.9 
22.0 
DuAl COIl uNITS
ElECTRIC bACKup uNITS
Table 2