Unigreen Trolleys and Barrows 用户手册

下载
页码 28
22
23
6.2 ROUTINE MAINTENANCE
Follow the instructions in the “Switching off” section and in the table below.
For appliances fitted with a combustion engine, remember to follow the instructions for routine 
maintenance  in  the  engine’s  operating  and  maintenance  instructions,  especially  as  regards 
controlling the engine oil, the air filter and the spark plug.
     WARNING
•  During use, the appliance should not be too noisy and large amounts of liquid or oil should 
not drip from underneath it.
In this event, a Skilled Technician should test the appliance.
6.2.1  Diaphragm rupture  
The rupture of one or more diaphragms can result in the mechanical parts of the pump being 
damaged by the liquids being pumped.
The following are symptoms of possible diaphragm rupture:
-  oil takes on a whitish appearance (symptom of water in the oil)
-  excessive consumption of oil
-  sudden lack of oil in the volumetric compensator (32).
     WARNING
•  To avoid the negative consequences of this malfunction, stop operation of the appliance 
immediately and contact a Skilled Technician without delay (within 24 hours) who will 
take the necessary action.
  If  it  is  not  possible  to  contact  a  Skilled  Technician  within  the  above  time  in  case  of 
ACTION
Each time used
Every 50 hours
INTERVAL FOR MAINTENANCE
Oil or lubricate rotating or sliding parts that are 
easily accessible for the operator.
Check the inflation pressure of the pressure 
accumulator (if any) and tyres.
Check the intake circuit.
Check the motor-driven pump is securely 
fastened to the appliance’s structure.
Should the motor-driven pump appear not to 
secure, do not use the appliance and 
contact a Skilled Technician.
Check level and status of pump oil
Check the intake filter, filling filter, and 
nozzleand clean, if necessary. Do not use hard 
or sharpobjects to clean the nozzle.
Check the supply cable, high-pressure 
hoseand spray lance, that the grips and 
couplings are secure and that any hooks (34) 
on the controlunit are inserted correctly.
Should any of these parts appear to 
bedamaged, do not use the appliance and  
contact a Skilled Technician.