Silicon Image Drive SSD-P08G(I)-3521 数据表

下载
页码 109
ATA C
OMMAND
 B
LOCK
 
AND
 S
ET
 D
ESCRIPTION
SSD-P
XXX
(I)-3521 D
ATA
 S
HEET
S
ILICON
S
YSTEMS
 P
ROPRIETARY
This document and the information contained within it is confidential and proprietary to SiliconSystems, Inc.
All unauthorized use and/or reproduction is prohibited.
3521P-02DSR
P
AGE
 90
F
EBRUARY
 2, 2009
Request Sense — 03h
The Request Sense command identifies the extended error codes generated
by the preceding ATA command. The Request Sense command must be
issued immediately following the detection of an error via the Error register.
The extended error codes are defined in the following table.
Table 76:  Request Sense — 03h
Register
D
7
D
6
D
5
D
4
D
3
D
2
D
1
D
0
Feature
X
Sector Count
X
Sector Number
X
Cylinder Low
X
Cylinder High
X
Drive Head
1
X
1
Drive
X
Command
03h
Table 77:  Extended Error Codes
Extended Error Codes
Description
00h
No error detected
01h
Self test is OK (no error)
09h
Miscellaneous error
20h
Invalid command
21h
Invalid address (requested head or sector invalid)
2Fh
Address overflow (address too large)
35h, 36h
Supply or generated voltage out of tolerance
11h
Uncorrectable ECC error
18h
Corrected ECC error
05h, 30h-32h, 37h,3Eh
Self test of diagnostic failed
10h, 14h
ID not found
3Ah
Spare sectors exhausted
1Fh
Data transfer error/aborted command
0Ch, 38h, 3Bh, 3Ch, 3Fh Computed media format
03h
Write/erase failed