Power Up Initial Display 
When powering on, the Caretaker Plus goes through a power up self-test which checks 
the main functions of its electronics. The leftmost LED labeled POWER should glow 
green and the other red LEDs should all turn on. Then the unit will cycle through four 
tests lighting up LEDs 1 through 4 as each test is performed. Errors are indicated by the 
ERROR LED lighting and the unit halting. See TABLE 6 for the full sequence of the 
power up LED display and TABLE 7 for error displays. 
 
Table 6. LED Power Up Display 
Legend: M = Mode LED    D = Data LED    B = Busy LED   E = Error LED 
               
 = LED on        O = LED off       ☼ = LED flashing 
               X = may vary, described below 
 
M  D  B   E 
1  2  3  4  5  6  7     8           EXPLANATION 
1
st
 
●  ●  ●  ●  ●  ●  ●  ●  ●  ●  ●  ● 
All LEDs on 
2
nd
 O  O  O  O 
● 
O  O  O  O  O  O  O 
Test 1: EPROM checker 
3
rd
  O  O  O  O 
  O  O  O  O  O  O 
Test 2: 16K RAM buffer 
 
O  O  O  O 
  O  O  O  O  O 
 
Test 2: 64K RAM buffer 
 
O  O  O  O 
  O  O  O  O 
●  ●
 
Test 2: 256K RAM buffer 
 
O  O  O  O 
  O  O  O 
●  ●  ●
 
Test 2: 512K RAM buffer 
 
O  O  O  O 
  O  O 
●  ●  ●  ●
 
Test 2: 1M RAM buffer   
 
O  O  O  O 
  O 
●  ●  ●  ●  ●
 
Test 2: 2M RAM buffer  
4
th
  O  O  O  O 
O  O 
  O  O  O  O  O 
Test 3: Static RAM 
 
5
th
  O  O  O  O 
O  O  O 
  O  O  O  O 
Non-volatile RAM 
 
6
th
  O  O  O  O 
O  O  O  O  O  O  O  O 
Unit ready 
 
NOTE: The BUSY LED may be lit when the unit enters the ready state.  This is 
dependent upon the state of the shared device. 
Program Checksum Test 
This test verifies that the unit's internal program is valid by performing a checksum test. 
If a fault exists, a program checksum error shows on the LEDs as error 1, as shown in 
TABLE 7. The unit will immediately halt. This error requires that the unit be serviced. 
Buffer Memory Sizing and Read/Write Test 
In this test, the Caretaker Plus automatically determines amount of buffer memory 
present and indicates the amount via the status LEDs as shown in TABLE a. The buffer 
memory is then tested to ensure that the memory system is operational. Any failure will 
cause the error 2 condition to be displayed, as shown in TABLE 7, indicating that a 
buffer memory data error has occurred. The unit will not continue its further tests and will 
halt. An error indicates that the unit requires servicing.