Long Test with Loopback 
This test is entered by pressing the advance switch only while powering up the unit with 
the on/off switch. Special loopback connectors should be connected to each Caretaker 
Plus port. 
Tests 1-5
 - These are the same as tests 1-5 of long test without loopback. 
 
Test 6
 - The loopback test assures that all port signals are functional. In order for this 
test to pass, special loopback connectors must be installed on each port, see TABLE 9. 
if this test fails (ERROR LED and LED #6 are lit) then a port communication chip has 
failed and the unit must be serviced. 
The advance switch may be pressed to determine which port is the failing port. MODE, 
DATA, and BUSY will all be flashing. The LEDs of all ports which pass will be flashing. A 
failing port will have its corresponding LED steadily lit (ERROR LED is used for port O). 
Ports not installed will have their corresponding LEDs off. The select switch may be 
pressed to execute the test again. In order to bypass this test completely, both the 
advance and the select switched may be pressed. 
 
Table 9. Loopback Test Connectors 
Serial Loopback 
Connector 
Male 25 Pin D 
Parallel Loopback 
Connector 
Male 36 Pin Centronics 
Parallel Loopback 
Connector 
Male 25 Pin D 
2……..….3 
6……….20 
1……..….8 
2……….13 
3……….32 
4……….12 
5……….31 
6……….36 
7…..10, 14 
9……….11 
1…..…….8 
 
3……….15 
4……….12 
5……….16 
6……….17 
7…..10, 14 
9……….11