Chapter 5
Image Acquisition
5-4
ni.com
Figure 5-1 illustrates the relationship between an external trigger, a lighting 
strobe, and the exposure time.
Figure 5-1.  Externally Triggered Mode
The trigger shown in Figure 5-1 represents an external trigger, configured 
to use the rising edge as the active edge. The time between the active edge 
of the trigger and the assertion of the lighting strobe is a user-configurable 
trigger delay. The trigger delay can be configured in either milliseconds or 
quadrature encoder counts. The NI 1722 does not support quadrature 
encoders.
1
User-Configurable Trigger Delay
2
Lighting Turn-On Time
3
Beginning of Image Readout
Trigger
Lighting Strobe
Exposure
Image Readout
3
2
1