Focus Tube Gasket 
Focus Tube 
TLM100 Gasket 
TLM100 Sensor Component 
Mounting Screws (x5) 
SAE 5-Bolt Tank Fitting 
TLM100 Interface Component 
1” (2.54cm) clearance 
between focus tube and 
tank bottom 
 
Figure 3 – Mounting TLM100 to SAE 5-Hole Tank with Focus Tube 
 
2.4.1.3  Installation on a Tank with a SAE J1810 5-Bolt Fitting and Airlock 
 
Installation of the TLM100 on a tank with a SAE J1810 5-bolt fitting with an airlock is identical 
to installation with a focus tube, except that the trimming step is eliminated. Please refer to 
Section 0 for details of the mounting procedure. 
 
2.4.1.4  Installation on a Tank with a 1.25”BSP or 1.5”NPT Threaded Tank Fitting 
 
For a threaded tank sender mounting hole, first thread the adapter into the tank opening and 
tighten to a torque of 3-5 ft-lbs (4.1-6.8 N·m). 
 
Next, place the TLM100 gasket over the adapter so that the bolt holes on the gasket line up 
with the bolt holes on the adapter (WARNING – the gasket must be properly aligned; it only fits 
one way). Place the TLM100 sensor component on top of the adapter so that the bolt holes on 
the TLM100 sensor component line up with the bolt holes on the adapter. 
  
Place the included mounting screws through the bolt holes on the TLM100 sensor component, 
and thread them into the adapter, tightening them to a torque of 10-15 in-lbs (1.1-1.7 N·m). Do 
not use threadlocking compounds containing methacrylate ester, such as Loctite Red (271), as 
they will cause stress cracking of the plastic enclosure. 
 
 
 