TROUBLEsHOOTInG GUIDE
PROBLEM
CAUSES
SOLUTIONS
The controller is continuously watering.
Too many start times have been programmed. Only one start time is necessary to activate a program.  
(refer to Setting Watering Start Times on page 7).
There is no display.
Check AC power wiring.
Correct any errors.
The display reads “No AC”.
There is no AC power present (the controller 
is not receiving any power).  
Check to see if the transformer is properly installed.
Display reads “Off,
 
 
 
”.
The rain sensor is interrupting irrigation or the 
sensor jumper has been removed.
Slide the rain sensor bypass switch to the BYPASS position to 
bypass the rain sensor circuit, or reinstall the jumper.
Rain sensor will not shut off the system.
Defective rain sensor.
Jumper was not removed when sensor  
was installed.
Stations have been programmed to override 
the sensor.
Verify operation of rain sensor and proper wiring
Remove jumper from the sensor  
terminals.
Reprogram the sensor override to enable the sensor 
(see page 10).
Frozen display, or showing incorrect 
information.
Power surge.
Reset the controller per page 11 “Clearing Controller Memory/
Resetting the Controller”.
Display shows “ERR” with a number (1-8).
Short in valve wiring circuit, or faulty solenoid 
on the station number indicated.
Check wire circuit or solenoid for the valve number indicated.  
Repair short or replace solenoid. Press any button to clear the 
“ERR” from the display.
Display shows “P ERR”.
Faulty pump relay or master  
valve wiring.
Incompatible or defective relay or solenoid.
Under sized wire to the pump relay or  
master valve.
Check wiring to relay or master valve solenoid. Press any button 
to clear the “P ERR” from the display.
Check electrical specification for the pump relay. Do not exceed 
controller's electrical rating. Replace if defective.
Replace wire with larger gauge wire.