Troubleshooting
Problem
Cause
Solution
Salty water
Plugged injector.
Low water pressure.
Drain line or flow control is restricted.
Brine line restricted or crimped.
Excessive amount of water in brine
cabinet.
Insufficient rinse time.
Intermittent pressure drop from feed
source.
Clean injector screen, nozzle and
throat (See Fig. 6)
Maintain minimum pressure of 30 psi
(See Engineering Specs.)
Remove restriction.
Remove restriction, replace if
crimped.
Verify correct water level relative to
salt setting. Check brine line and fit-
tings for loose connections (See
Brine Cabinet Data, page 36.)
Check mode setting chart (pg. 14-
15) for proper brine rinse time.
Adjust time, if necessary.
Install check valve on the inlet water
line to the appliance. (Check local
plumbing codes first.)
NOTES:
19