England's Stove Works 25PAH 用户手册
Page | 5
SPECIFICATIONS
Heating Specifications
Heat Output Range** ............................................ 11,000 BTU/hr – 25,000 BTU/hr
Approximate Pellet Burn Rate** ............................................... 1.6 lb/hr – 4.0 lb/hr
Maximum Burn Time** .............................................................................. 72 hours
Approximate Square Footage Heated*** ..................................... 800 ‐ 2000 sq. ft.
Hopper Capacity ..................................................................................... 120 pounds
Approximate Pellet Burn Rate** ............................................... 1.6 lb/hr – 4.0 lb/hr
Maximum Burn Time** .............................................................................. 72 hours
Approximate Square Footage Heated*** ..................................... 800 ‐ 2000 sq. ft.
Hopper Capacity ..................................................................................... 120 pounds
Dimensions
EPA and Safety Compliance Specifications
EPA and Safety Compliance Specifications
EPA Compliance ...........................................................................................Certified
Particulate Emissions ..........................................................................1.55 grams/hr
Efficiency* ........................................................................................................... 78%
Tested To ........................... ASTM E 1509, ULC/ORD‐C1482‐M1990 & ULC S627‐00
Particulate Emissions ..........................................................................1.55 grams/hr
Efficiency* ........................................................................................................... 78%
Tested To ........................... ASTM E 1509, ULC/ORD‐C1482‐M1990 & ULC S627‐00
*‐ This unit was not tested for efficiency; the efficiency shown is a default value normally attained by similar, certified pellet burning appliances.
** ‐ Heat output, burn rate and maximum burn time are heavily dependent on the type of pellets burned in the stove; as such, these numbers
may vary.
*** ‐ The maximum heating capacity of this unit can vary greatly based on climate, construction style, insulation and a myriad of other factors.
Use this information in conjunction with a BTU loss calculation for your home to determine if this unit will be sufficient for your needs.
** ‐ Heat output, burn rate and maximum burn time are heavily dependent on the type of pellets burned in the stove; as such, these numbers
may vary.
*** ‐ The maximum heating capacity of this unit can vary greatly based on climate, construction style, insulation and a myriad of other factors.
Use this information in conjunction with a BTU loss calculation for your home to determine if this unit will be sufficient for your needs.
12.125 in.
5.5 in.
24.25 in.
24.25 in.
31.
3
1
2
5
in.
8.
4375
in.
7.
00
in
.