Notes on using UG00P-DI (Dual Port Interface)
As the UG00P-DI is powered by a CPU, check that the electric capacity of the CPU is at 5V (power
consumption: max. 350mA).
The distance between the CPU and the UG00P-DI should be as short as possible (max. 1 to 1.5m).
For wiring, take appropriate measures to eliminate noise.
Specify the value more than 150 (=1.5 s) in [Time-out Time] of [Comm. Parameter] in case of
connecting POD to a UG00P-DI.
GD
G
P
P
1 2 3
POWER
RUN
BATT.V
MELSEC
  
FX2-24MT
  TRANSISTOR UNIT
FX Series CPU
A6GPP, A7PHP, personal computer, etc.
UG200C-G
POD
Slide switch 
1 • • • A series 
2 • • • QnA series 
3 • • • FX series 
*
Note: 
Be sure to turn the power off 
when changing over of the 
sliding switch.
*
When use the cable "UG00C-E", it is impossible to use the UG00P-DI.
In case of direct connection with the CPU port of FX1/2 
series, use the cable "
UG200C-G
"
 (separately sold)
.
In case of direct connection with the CPU port of 
FX2N/1N/0N/1S series, use the cable "FX-20P-CADP" 