(8) INITIALIZE   
Present settings are reset to the factory default settings. 
 
 
 
 
 
 
 
 
Fig. 8  INITIALIZE MENU 
 
     Fig.14 INITIALIZE menu 
 
Operation procedure 
1. Move the cursor to INITIALIZE and press the SW. INITIALIZE menu is displayed. 
2. Move the cursor to OK and press the SW. All parameters and adjustments are reset to the factory 
default settings. 
3. The screen automatically reverts to MAIN MENU when the initialization is finished. 
 
Note) Even if this function is executed, the following item is not initialized. 
ADDRESS and COM SPEED on CAMERA SETUP menu 
Adjustment value of PHASE on SYNC SELECT menu 
Blemish Compensation 
 
The fig.14 shows parameters after executing INITILIZE. (factory default settings) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fig.15    Setting parameters of INITIALIZE 
En-23 
INITIALIZE 
 
  ALL SETTINGS ARE 
  IINITIALIZED 
     
 
 
 
 
 
    OK                            CANCEL 
EXPOSURE SET. 
     
    AE MODE               
    LEVEL 
       
    FLICKERLESS                 
    AGC                           
    SENS UP                 
    DAY&NIGHT         
  DETECT TIME  
    FILTER LIMIT 
 
  RETURN               END 
FUNCTION SET. 
     
    SYNC SELECT               
    WHITE BALANCE 
       
    CROMA                 
  *GAMMA                     
  *E-ZOOM                 
    MASKING         
    TITLE   
     
 
  RETURN               END 
→     
→    AUTO 
→     
→ NORMAL
→     
→     
→       
 
→        WD 
→          0 
→        OFF 
→        ON 
→          4 
→      AUTO 
→   5sec 
→  10min 
CAMERA SETUP   
 
  ADDRESS    
  COM SPEED          
    LED                               
  SWITCH                       
 
 
 
 
 
  RETURN               END 
→      1 
→  4800 
→    ON 
→    ON