individual P2ZCIM units at least one P2ZCIM must be powered ON; in 
P2ZCIM chains from 21 to 42 P2ZCIM units, at least 15 P2ZCIMs must 
be powered ON. 
 
P2ZCIM LED Status 
The LED on each P2ZCIM indicates its operational state: 
•  If the LED blinks rapidly: P2ZCIM does not have a confirmed 
Communication Address. 
•  If the LED is primarily off and blinks on every two (2) seconds: 
P2ZCIM has a confirmed Communication Address but is not 
switched to that Address. 
•  If the LED is on and blinks on/off rapidly when there is 
keyboard/mouse traffic: CIM has a confirmed Communication 
Address and is switched to that Address. 
Note: The P2ZCIM will blink from time to time even if there is no 
keyboard/mouse traffic; this demonstrates that the P2ZCIM is 
operating normally and not locked. 
•  If the LED is blinking on and off but at a regulated, moderate speed 
(that is, every half second): that P2ZCIM is acting as Manager of the 
chain. 
 
Paragon II and Z-CIMs 
Z‐CIM installation requires that servers are assigned names when added 
to the Z‐CIM chain. The default name of any Z‐CIM is its serial number, 
which is not meaningful to you. In order to name the Z‐CIM, it must be 
connected to a server that is powered on and to the Paragon switch to get 
status and name assignment. 
To organize and track Z‐CIMs and the servers to which they are 
connected, we recommend one of two methods: 
•  Record the serial numbers of the Z‐CIMs connected to each server, 
and then name all Z‐CIMs at one time after the chain is complete. 
•  First complete the chain and then power on the Z‐CIM one at a time, 
checking the serial number on the Z‐CIM as it is connected, and 
assigning the proper name to the proper server Z‐CIM. 
When naming or renaming a Z‐CIM, switch to that Z‐CIM to activate it, 
thereby ensuring that its new name is updated in the Paragon switchʹs 
database.