Case 8. Creating Multiple Paths to the Same Server(s) 
 
xvi
 
 
 
6.  When you complete your work, press the hot key (default: Scroll 
Lock) twice quickly to trigger the On‐Screen User Interface (OSUI). 
See Using the OSUI for Initial Configuration (on page 22) for details. 
7.  Press Shift +F9 to disconnect the server, and then remove the card. 
See Using the Card Reader (on page 81) for details. 
The cardʹs authentication data is not stored in the Paragon system so you 
must repeat Steps 3 to 5 if you want to access the same server again. 
 
Case 8. Creating Multiple Paths to the Same Server(s) 
Purpose: To ensure that there is redundant access to specific servers. In 
this example, we will create four available paths for access to specific 
servers using the structure of multiple Base Units. 
Note: A Base Unit is a “first‐tier” Paragon switch. 
1.  Prepare six Paragon switches, such as P2‐UMT1664M and/or 
P2‐UMT832M. 
2.  Choose three of them as Base Units, two as the 2
nd
 tier, and one as the 
3
rd
 tier. If these switches do not share the same firmware version, 
make sure the versions of lower tiers are later than those of upper 
tiers. For example, Base Unit is with firmware version 4.2 and 2
nd
 Tier 
with version 4.0. 
3.  Connect all of these Paragon switches with Category 5 (Cat 5) UTP 
cables from the channel ports of lower tiers to user ports of upper 
tiers as illustrated below: 
 
 
C 
Channel ports 
U 
User ports 
1(A) ~ 1(C) 
Base Units (first‐tier Paragon switches)