RGB Spectrum SuperView 3000 Video Windowing System 用户手册

下载
页码 64
May 9, 2002
SuperView 3000 User Manual
53
C
..
...
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
U
PDATING
S
YSTEM
F
IRMWARE
The firmware version in the SuperView can be field updated via the RS-232
serial port. The firmware is like the operating system in your computer—it
instructs the SuperView in all of its operations.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Required for the procedure:
1. Computer or terminal capable of serial communications at a 115,200
baud rate;
2. Current firmware update file and update instructions
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Do not proceed to update firmware without these two items!
If a firmware update has been published, the file can be downloaded from the
RGB Spectrum website at http://www.rgb.com, in the Support section. The
firmware would also be available on disk directly from RGB Spectrum.
Instructions and release notes accompany the update file.
Note: The update firmware process cannot be used from within the SuperView
VCP control software. You must use a terminal emulation program—such as
HyperTerminal or Procomm—or a dumb terminal capable of communicating at
115,200 bps.
After the firmware update procedure is complete, the system is restored to
factory defaults. The baudrate is set to 9600 bps and all data previously stored
to the EEPROM is erased.