3 – Connections
16
 TASCAM DS-M7.1
Inserts
Either analog or digital insert units can be connected 
to operate after the 
BUS/RTN
 switch. These are 
selectable pre- or post- the Input Summing Router.
These inserts can be pre- or post- the input summing 
router (placed between the inputs and the RTN/BUS 
selector switch) and always pre- the RTN/BUS 
switch. See the block diagram at the end of this man-
ual for details.
Either AES/EBU digital devices, or analog (standard 
+4dBu balanced) may be used here. Note that when 
making connections to an analog insert unit, because 
of the nature of the connectors used, two connections 
need to be made, one for input and one for output.
After the connection has been made, you should set 
up the insert as follows:
1
Press the 
INSERT
 key so that the screen 
shows something like:
2
There are three parameters. Use the cursor 
keys to select them. First, select whether the 
insert loop is enabled (
ENABLED
) or dis-
abled (
DISABLED
).
3
Next, select the position of the insert loop, as 
described above: either 
PRE SUM 
or 
POST SUM
 (i.e. before or after the input 
summing router).
4
Finally, set the 
Return
 type: 
ANALOG
 
(analog) or 
DIGITAL
 (digital).
Monitor connections
There are two sets of monitor connections, analog 
and digital.
The analog connections are standard balanced 
+4dBu connections, and the digital outputs are in 
AES/EBU format.
NOTE
The sampling frequency output from the digital moni-
tor outputs is the input frequency. If you are mixing a 
high sampling frequency project, you must therefore 
make sure that your digital monitoring setup can han-
dle these frequencies, or use the DS-M7.1’s analog mon-
itoring ports.
The analog and digital signals are output in parallel, 
and there is no switching between them.
TIP
The AES/EBU monitoring signals can be used in parallel 
with the analog monitoring signals to drive a suitably-
equipped meter bridge.
However, there is one setting that can be made for the 
AES/EBU digital ports; the “pick-off” point for the 
monitoring.
This can be set so that all the downmix, bass manage-
ment and delay settings, together with all muting and 
soloing and level settings described in “Other moni-
toring settings” on page 17, a
re ignored, or so that 
these settings take effect through the digital port. 
This affects the digital outputs only—the analog out-
puts will always reflect these settings.
7
Frequency error
The master clock is not a recognized frequency (e.g. 32 kHz). Check the master set-
tings and correct, if necessary.
8
AES/EBU preamble error (normal)
At normal sampling frequencies, the preamble of the AES/EBU signal acting as the 
clock source cannot be read by the DS-M7.1. Check and correct settings on the clock 
master.
9
AES/EBU preamble error (high-speed) At high sampling frequencies (88.2 kHz and 96 kHz), the preamble of the AES/EBU 
signal acting as the clock source cannot be read by the DS-M7.1. Check and correct 
settings on the clock master.
Error 
number
Meaning
Appropriate action to take
[ I N S E R T ]
S t a t e
D I S A B L E D
M o d e
P O S T
S U M
R e t u r n
A N A L O G