NDC comm NWH650 用户手册

下载
页码 61
  InstantWave 
High Rate
 
11Mbps
 
Access Point  
45 
 
Troubleshooting 
This section provides you with some troubleshooting info should you encounter 
installation or operation problems on InstantWave High Rate products.  If the 
problems still cannot be remedied after going through the Troubleshooting section, 
check the FAQs at 
If you still have a problem, contact NDC technical support for assistance (see 
Technical Support, page 47).  
 
Before going through the following troubleshooting information, run the AP Self 
Diagnostic Test
 to ensure the major AP components are working. 
 
If your problems still cannot be remedied after going through this Troubleshooting 
section, contact NDC technical support for assistance (see Technical Support, page 
47). 
 
Symptom Suggested 
Solutions 
The Power LED on the 
AP is OFF. 
1.  Make sure the power adapter is firmly connected to 
the power outlet and the AP power connector. 
 
The InstantWave HR 
APMS utility cannot 
detect an InstantWave 
HR AP on the same 
network.  
1.  Make sure the AP is powered on and connected to 
an Ethernet work. 
 
Check the IP addresses assigned to the AP and APMS 
terminal PC.  They should be in the same subnet and 
unique.  For example, if the AP’s IP address is 
192.168.1.5 with a mask of 255.255.255.0, then the 
PC’s IP address should be 192.168.1.x with a mask of 
255.255.255.0.  Consult your network administrator 
for exact settings. 
 
The AP powers up, but 
the Ethernet Link LED is 
OFF (no connection to 
an Ethernet network). 
Make sure: 
1.  The Ethernet cable is connected firmly to both the 
AP and Hub/Switch. 
 
3.  The Hub/Switch is powered on. 
 
4.  Your Hub/Switch port may be set to the “Uplink” 
position.  Set it to the normal position. 
 
The Status LED on the 
AP panel is Red and 
flashing.   
Restart (power cycle) the AP and check the Status 
LED again.  If it is still flashing, you need to return the 
AP to the reseller for repair.