Condition
Probable Cause
Solution
Small/no burner flame
Regulator failure
Unplug regulator vent hole or
replace regulator.
Plugged orifice hood
Unplug hole or replace orifice.
Plugged burner port
Unplug burner port(s).
Small/no pilot flame
Pilot valve setting
Adjust flame height.
Plugged pilot tip
Unplug pilot ports.
Yellow burner flame
Improper air shutter setting
Increase air shutter setting until
flame is blue.
Enlarged orifice hood
Replace w/correct orifice.
Flame lifts off burner
Improper air shutter setting
Decrease air shutter setting
until flame sits on burner.
Plugged orifice hood
Unplug orifice hole or replace orifice.
Improper level setting
Adjust level w/feet or shims.
Too hot/cold
Improper control setting
Adjust control setting or replace
 control.
Improper level setting
Adjust level w/feet or shims.
Too much/little lava rock
Add/remove lava rock to proper
level; single layer only with air
space.
The Connerton Company warrants to the original user for a period of one year from date of installation, not 
to exceed 18 months from date of shipment by Connerton, that the equipment manufactured is free from 
defects in material or workmanship.
Our obligation under this warranty shall be limited to furnishing without charge any part of said product 
which, upon examination by The Connerton Company shall prove to be defective. Parts wear is not 
considered a defect. The Connerton Company will not be responsible for labor or transportation charges 
incidental to the replacement of same.
The Connerton Company assumes no responsibility for failure of the equipment to operate properly due to 
improper installation or operation. This warranty applies to all equipment that has been unaltered, properly 
installed and maintained in accordance with national and local codes and in accordance with the 
installation and operating instructions included with this equipment.
This warranty does not extend to normal maintenance items, including but not limited to, air and gas 
adjustments and adjustments to pilot flames. Proper installation, adjustments, and initial checkout is the 
responsibility of the dealer, the owner-user or installer and not that of The Connerton Company.
Exceptions to warranty: 
1) Lower lava rock broiler grates.  
TROUBLESHOOTING GUIDE
Please fill out and refer to the following when contacting the factory:
Model # RLRB-23-         -A Serial#
Gas Type:
Purchase Date:
LIMITED WARRANTY