11
11-8
McDATA UltraNet Edge 3000 User Guide
Upgrading the UltraNet Edge 3000 Software
This will reset the UltraNet Edge 3000 and bring up the 
maintenance IP address.
8. Using Windows Dial-up Networking, establish a PPP session 
from the local PC to the new UltraNet Edge 3000.
9. Using the most current version of UCM, display the network map 
created in the previous version of UCM. 
10. Start the Hardware Replacement Wizard by right-clicking on the 
UltraNet Edge 3000 node>Tools>Replace Node (Hardware 
Replacement)
 for the new UltraNet Edge 3000. 
11. Update the serial number and license information.
12. Deliver the configuration to the new UltraNet Edge 3000. 
FTP the New UltraNet 
Edge 3000 Software
Use the following procedure to FTP to the new UltraNet Edge 3000 
and retrieve the new software:
1. Telnet to the new UltraNet Edge 3000 and issue the 
abort
 
command. 
This will boot up the UltraNet Edge 3000 and invoke the new 
configurations.
2. Telnet to the UltraNet Edge 3000 that is currently running OS 
3.1.1.1 (or any subsequent OS 3.x.x.x version).
Where xxx = the version of the UltraNet Edge 3000 before the 
upgrade.
3. Issue the 
tankio down x
 (where x = circuit ID 1, 2, etc) command 
for every defined circuit.
4. Issue the following commands:
— Edge> 
net ftp xxx.xxx.xxx.xxx
  
(where xxx.xxx.xxx.xxx = the IP WAN address of the new 
UltraNet Edge 3000) 
— Name  <xxx.xxx.xxx.xxx>: press 
ENTER
— Password: xxxxxxxx  
(where xxxxxxxx = the proper password)
A successful FTP login should occur. 
5. The output to the screen should read, “Using binary mode to 
transfer files”. If not, issue the 
binary
 command at the FTP 
prompt.