NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Required Clearances
WARNING:    BE  ABSOLUTELY  SURE  THE  DISTANCE  BE-
TWEEN THE HEATER AND THE SURFACE OF ANY COM-
BUSTIBLE CONSTRUCTION IS NOT LESS THAN SHOWN 
ON THIS PAGE.
Notes
•  Facing material that projects more than /4” (19mm) from 
the wall is considered a mantel or side wall.
•  MINIMUM FIREPLACE OPENING  22-1/2” (72mm) High x 
28-1/2” (724mm) Wide
Top Facing / Trim
Side Facing Materia
l
SIDE WALL
C
E (USA)
D
B
A
COMBUSTIBLE MANTEL
Insert
Maximum Mantel Depth = 9” (229 mm)
Hearth Protection
(Canada)
*  Reduced  clearances  may  be  available  for  A,  B,  C  and  D 
dimensions  per  NFPA  211  -  latest  edition,  Standard  for 
Chimneys,  Fireplaces,  Vents,  and  Solid  Fuel-Burning  Ap-
pliances (in Canada CSA B - latest edition). See section 
on “Reduction of Appliance Clearance with Specified Forms 
of Protection.” 
** Side view of optional mantel deflector shown.
(1)Hearth extension reductions: 2” (1mm) reduction for 2” 
(1mm) raised hearth.  (USA & Canada) 24” minimum hearth 
extension on all stoves as measured from the door opening of 
the unit (1" [40mm] minimum hearth extension on all inserts 
as measured from the door opening of the unit). Minimum 
distance of floor protection to the side = 8” (200mm). This 
is measured from the sides of the door opening in the USA 
and from the sides of the insert in Canada.
(2)J  =  Maximum  lintel  depth  without  flue  offset  or  smoke 
deflector.
Hearth Protection
The hearth and/or floor protection must be a thermally 
rated non-combustible hearth/floor protector meeting or 
exceeding a thermal rating of k=.84 or equivalent with 
a listed thickness of /4" (19mm) minimum in USA and 
Canada.  The covering must extend 24” (10mm) in front 
of the heater and 8” (200mm) to either side (measured 
from door opening in the USA and measured from the side 
of the unit in Canada).
M
6-1/2”
165mm
F
**
J
G
H
Mantel
Hearth Protection
Trim
9”
229mm
Model
*A
*B
*C 
*D
E(1)
C10
 
 
USA-30”
CAN-787mm
USA -20”
CAN-584mm
20”
508mm
1”
381mm
8”
200mm
C10
 
with 
mantel 
and/or side 
shields
22”
559mm
12”
305mm
20”
508mm
8”
200mm
8”
200mm
Model
F (1)
G
H
J(2)
M
C10  
24”
610mm
14-1/2”
368mm
22-1/2”
572mm
-1/4”
133mm
0-1/2” 
1283mm
C10 with mantel 
and/or side 
shields
24”
610mm
14-1/2”
368mm
22-1/2”
572mm
-1/4”
133mm
0-1/2” 
1283mm
Figure 4
Figure