Amana AGK01 安装指导

下载
页码 20
8
Chassis
Wall Sleeve
Outside
Wall
Screws
(3 on each
side of unit)
Chassis Installation View 2
Installation Instructions
Wiring
WARNING
T
O AVOID PROPERTY DAMAGE, PERSONAL INJURY OR DEATH DUE TO
ELECTRICAL SHOCK, DO NOT SERVICE THIS UNIT WITHOUT FIRST SHUTTING OFF
POWER TO THE UNIT FROM THE CIRCUIT BREAKER AND/OR REMOVING
THE UNIT CORD SET PLUG FROM THE WALL OUTLET.
CAUTION
T
O AVOID PROPERTY DAMAGE, PERSONAL INURY OR DEATH DUE TO
ELECTRICAL SHOCK, DO NOT USE AN EXTENSION CORD WITH THIS UNIT.
CAUTION
T
O AVOID THE RISK OF PROPERTY DAMAGE, PERSONAL INURY OR FIRE,
USE ONLY COPPER CONDUCTORS.
CAUTION
T
O AVOID THE RISK OF PERSONAL INURY, WIRING TO THE UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
Cord connection to a wall socket is not permitted for 265-volt
units.  All 265-volt units must be hard wired using the hard wire
kit or make use of the plug-in receptacle in the standard subbase.
230/208V and 115V units are equipped with LCDI or AFCI power
cords and can open the electrical circuit to the unit.  In the event
the unit does not operate, check the reset button located on or
near the head of the power cord as part of the normal trouble-
shooting procedure.
WARNING
T
HIS AIR CONDITIONER IS NOT MEANT TO PROVIDE UNATTENDED COOLING OR
LIFE SUPPORT FOR PERSONS OR ANIMALS WHO ARE UNABLE TO REACT TO 
THE FAILURE OF THIS PRODUCT.
T
HE FAILURE OF AN UNATTENDED AIR CONDITIONER MAY RESULT IN EXTREME
HEAT IN THE CONDITIONED SPACE CAUSING OVERHEATING OR DEATH OF 
PERSONS OR ANIMALS.
P
RECAUTIONS MUST BE TAKEN TO WARN OFF OR GUARD AGAINST SUCH AN
OCCURRENCE.
PTAC WIRE HARNESS KIT (PWHK01C)
See PTAC Wire Harness Kit Installation Instructions for
proper wire orientation and location for low voltage wiring.
HEATERLESS UNITS
If a heaterless unit is ordered, field provisions must be made for
adding supplemental heat. Refer to the Installation Instructions
supplied with the heater kit for a complete description of the
installation procedures. All 208/230 volt heaterless units are
shipped with a 15 Amp power cord and all heaterless 265 volt
units are shipped with a 20 Amp power cord.
When adding a heater kit to a heatless unit, the power cord
supplied with the heater kit must be used in place of the power
cord supplied with the unit.  Table 1 specifies power cord rating
requirements for the various heater kits.
4.
Secure the chassis to the wall sleeve using three screws on
each side of the chassis to ensure a proper seal between the
chassis and the wall sleeve.  The screws are supplied in a
plastic bag attached to the power cord.
IMPORTANT NOTES:
1.
The unit is equipped with a rubber grommet mounted com-
pressor. These grommets are factory set and require no ad-
justment.
2.
If a standard subbase is used, be sure the right hand subbase
cover is removed before the chassis is installed in the sleeve.
3.
On 230V,30A units installed with an existing subbase, use the
subbase cover extension kit.
4.
Check the indoor and outdoor grilles for obstructions to air
flow. The unit must be located where curtains, furniture, trees,
or other objects do not block the air flow to and from the unit.
If air is obstructed and/or deflected back into the unit, the air
conditioner compressor may cycle on and off rapidly. This
could damage the compressor or possibly void the warranty.