Amana PTH123G50AXXX 目录

下载
页码 16
12
www.amana-ptac.com
MC-DPTAC
a
ccessories
 (
conT
.)
t
heRmoStatS
The following thermostats offer remote control. Any thermostat other than those listed must be submitted to Goodman Company, L.P., for approval prior to use.
PDK3A
230/208V – R-22
PDK4A
265V – R-22
PDK3E
230/208V – R-410A
PDK4E
265V – R-410A
P
oWeR
 d
ooR
 K
it
 
Vent door will automatically open when unit fan is on.
HWK03B
Hydronic Water Kit – R-22
HVK03B
Hydronic Steam Kit – R-22
HWK03E
Hydronic Water Kit – R-410A
HVK03E
Hydronic Steam Kit – R-410A
h
ydRoniC
 h
eat
 K
it
Add-on  kits  fit  all  units  allowing  the  addition  of  hydronic  water  or  hydronic
steam heat to cooling and heating units. The kits feature left- or right-hand 
piping. Unit retains complete service access with a kit installed. Unit must be 
connected to and operated by a wall thermostat.
Hydronic Heat Kit-Top View
Hydronic Heat Kit-Right View
Hydronic Heat Kit-Side View
VS2WNCA*
2-way/24V/NC/Steam
VS2WNOA*
2-way/24V/NO/Steam
VW2WNCA*
2-way/24V/NC/End Switch
VW2WNOA*
2-way/24V/NO/End Switch
VW3WNC2B*
3-way/24V/NC/NO/End Switch
* Pop-top Actuator
h
ydRoniC
 v
alveS
Water and steam valves are available for use with the HWK03 (water) and HVK03 
(steam) heat kits. 
KL03B
Security Key Lock (R-22)
KL03E
Security Key Lock (R-410A)
S
eCuRity
 K
ey
 l
oCKS
In conjunction with the tamper-resistant front, the installation of Amana® brand
security key locks prevents tampering of the controls used to set temperature, 
heating and cooling functions. UL approved for institutional use only.
RTS03
Remote wall-mounted sensor
R
emote
 t
emPeRatuRe
 S
enSoR
Unit can be wired to sense room temperature away from the PTAC to have 
accurate readings.
DS01E
Thermostat: 2-way communications
DD01E
Occupancy Sensor: EMS activation
DT01A
Antennae / Router
GT01A
Generic Radio Antenna / Router
DD01F
Door Switch: EMS Activation
DP01E
Web-enabled Platform Server
DL01E
Web-enabled Platform Server Link
W
iReleSS
 Rf (R
adio
 f
RequenCy
) C
ontRolS
All DigiSmart PTACs come factory-ready to be controlled via wireless RF devices.
2.4 Ghz 802 15.4 protocol assures robust communications and response.
Model #
Heat
 Stages
Cool
Stages 
Fan
Speed
# of Wires
Required
Temp
Limiting
Backlit
Display
Type
Shape &
Orientation
Connection
2246002
1
1
1
5
No
Yes
Digital
Manual
Rect./Horiz.
Wired 
2246003
2
2
2
7
Yes
Yes
Digital
Manual
Rect./Horiz.
Wired 
2246007
2
2
2
7
Yes
Yes
Digital
Auto-Change
Rect./Horiz.
Wired 
2246008
2
2
2
7
Yes
Yes
Digital
Programmable
Rect./Horiz.
Wired
DS01E 
2
2
2
0
Yes
Yes 
Digital
Manual
Rect./Horiz.
Wireless