Specifications  
subject to change.
FRIGIDAIRE
USA 
 
Electrolux Major Appliances, North America 
 250 Bobby Jones Expressway 
 Martinez, GA 30907 
 1-800-FRIGIDAIRE 
 
frigidaire.com 
CANADA 
• 
Electrolux Canada Corporation 
 5855 Terry Fox Way 
 Mississauga, ON L5V 3E4 
 1-800-265-8352 
 
frigidaire.ca
FGMV185K 04/09 
© 2009 Electrolux Home Products, Inc. 
Printed in the U.S.A.
Microwaves
FGMV185K F/ W/ B    
Over-The-Range
Microwave Specifications
 Product Shipping Weight (approx.) – 70 Lbs.
 Voltage Rating – 120V / 60 Hz / 15 Amps
 Connected Load (kW Rating) @ 120 Volts = 1.65 kW  
(For use on adequately wired 120V, dedicated circuit having 2-wire 
service with a separate ground wire. Appliance must be grounded  
for safe operation.)
 Amps @ 120 Volts = 14.3 Amps
 Always consult local and national electric codes.
 Grounded outlet should be located in cabinet above, with hole in base 
to route power cord. Carefully follow top template instructions for 
power cord clearance when installing beneath smooth, flat cabinets.
 Microwave’s exhaust ventilation system is preset to recirculate air 
inside with no ducting system required. Exhausting air outside is 
optional, using either vertical or horizontal ducting system. (Refer to 
Ducted Option Specifications for outside ventilation.)
 For safe and proper installation, microwave MUST be mounted to 
BOTH a top cabinet AND a wall, and connected to at least one wall 
stud. Can NOT be installed in island or peninsula cabinet arrangements.
 Cabinet bottom MUST be level to insure proper installation.
 Cabinet MUST be capable of supporting a total load of 110 lbs.
 Filler blocks recommended for installation when cabinet front hangs 
below recessed bottom shelf.
 Minimum distance of 30" required from cooking surface to bottom 
edge of top cabinet.
 Minimum distance of 66" required from floor to top of microwave.
 Opening between cabinets MUST be 30" wide and free of obstructions. 
For openings up to 36" wide, order optional 36" Filler Panel Kit to fill  
in gap between unit and cabinets.
 Allow 26" minimum clearance for 90° door swing.
Ducted Option Specifications
 For outside ventilation.
 Exhaust duct adapter will be needed for outside ventilation, to mate 
with standard 3-1/4" x 10" rectangular duct. If round duct required, 
rectangular-to-round transition adapter will be needed with no less 
than 6" diameter.
 For most efficient airflow exhaust, use a straight run or as few elbows 
as possible with a maximum duct length of 3-1/4" x 10" rectangular or 
6" diameter round duct, not to exceed 140 equivalent feet.
 For horizontal installation, be sure to allow enough space between 
wall studs to accommodate exhaust.
 Refer to installation instructions on web for detailed duct  
preparation and converting exhaust vent blower system for exterior 
exhaust ventilation.
Note:  For planning purposes only. Refer to Product Installation Guide  
on the web at frigidaire.com for detailed instructions.
Optional Accessories
36" Stainless Steel Filler Panel Kit – (PN # MWFILKTSS).
36" White Filler Panel Kit – (PN # MWFILKTWH).
36" Black Filler Panel Kit – (PN # MWFILKTBK).
30" Over-the-Range Microwave Oven w/Side Controls
Gallery (1.8 Cu. Ft.)