Viking VGSU5366BSS 安装指导

下载
页码 20
Electrical Requirements
There is no connection necessary beyond
plugging the unit into a polarized,
grounded, 120 volt, 60 Hz, 15 amp circuit. A
minimum of 120VAC is required for proper
operation of gas ignition systems. DO NOT
use a GFI circuit. This circuit, however,
MUST be grounded and properly polarized.
The unit is equipped with 16-3 SPT2 power
cord. 
Note: 
If electrical power is not supplied or is
interrupted, the open top burners will have
to be lit manually with a match.
Gas Connection
The gas supply (service) line must be the
same size or greater than the inlet line of the
appliance. All cooktops use a 1/2” (1.3 cm)
I.D. NPT (Sch40) inlet. Sealant on all pipe
joints must be resistive to LP/Propane gas.
These cooktops are designed specifically for
natural gas. An (LP) gas conversion kit must
be purchased separately. Before beginning
installation verify that the model is
compatible with the intended gas supply.
IMPORTANT: Any conversion required
must be performed by a qualified licensed
plumber or gas service company. The
proper conversion kit must be ordered
from your authorized service agency or
dealer.
Manual shut-off valve:
• The installer-supplied valve must be
installed in the gas service line ahead of
the appliance and regulator in the gas
stream and in a position where it can be
reached quickly in the event of an
emergency. 
In Massachusetts: A “T” handle type
manual gas valve must be installed in 
gas supply line to the appliance.
Pressure regulator:
• All heavy-duty, commercial-type cooking
equipment must have a pressure regulator
on the incoming service line for safe and
efficient operation, since service pressure
may fluctuate with local demand. The
regulator supplied with the cooktops must
be installed before any gas connections
are made.
• Manifold pressure should be checked with
a manometer; natural gas requires 5.0”
WCP and LP/Propane requires 10.0” WCP.
Incoming line pressure upstream for the
regulator must be 1” WCP higher than the
manifold pressure in order to check the
regulator. The regulator used on this
cooktop can withstand a maximum input
pressure of 1/2 PSI (14.0” WCP). If 
the line pressure is in excess of that
amount, a stepdown regulator will be
required.
•  The appliance must be disconnected from
the gas supply piping system during any
pressure testing of that system.
Rigid Connections:
• Incoming gas is brought from an intake
pipe (not supplied) at the rear of the unit
to the pressure regulator; then to the
manifold pipe for distribution. The only
connection necessary is from the service
supply, through the shut-off valve (not
supplied), to this intake pipe (not
supplied) to the regulator supplied, but
not connected through the cooktop.
In Massachusetts: This appliance must be
installed with a 36” (3-foot) long flexible gas
connector.
LP/Propane Conversion
The VGC/VGSU models are field convertible
to LP/Propane gas. The orifice spuds and
regulator must be physically changed. See
conversion kit and instructions which must
be purchased separately. Gas conversions
and initial installation adjustments are not
the responsibility of the manufacturer.
14
Electrical & Gas Requirements