induction cooKtoP inStALLAtion inStRuctionS
WARNING
 An extension cord must not be used 
with this appliance. Such use may result in a fire, 
electrical shock, or other personal injury.
3.  the appliance should be connected to the fused
disconnect (or circuit breaker) box through 
flexible armored or nonmetallic sheathed cable. 
the flexible armored cable extending from this
appliance should be connected directly to the
grounded junction box. the junction box should be
located as shown in Figure 2 with as much slack
as possible remaining in the cable between the box 
and the appliance, so it can be moved if servicing
is ever necessary.
4.  A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.
Unpacking Instructions
1.  Unpack and visually inspect the cooktop.
2.  Be sure the bottle of cleaner conditioner packed 
in the literature bag is left where the user can 
find it easily. It is important that the ceramic-glass
cooktop be pretreated before use. See
Cooktop 
Cleaning and Maintenance section in the Use 
and Care Guide
.
Electrical Connection
Connect the flexible armored cable that extends from
the surface unit to the junction box using a suitable 
strain relief at the point the armored cable enters the 
junction box. then make the electrical connection as
follows.
Electrical ground is required on this appliance.
 This appliance is equipped with a 
copper conductor flexible cable. If connection 
is made to aluminum house wiring, use only 
special connectors which are approved for joining 
copper and aluminum wires in accordance with 
the National Electrical Code and local codes and 
ordinances. Improper connection of aluminum 
house wiring to copper leads can result in a short 
circuit or fire. Follow the connector manufacturer 
recommended procedure closely.
this appliance is manufactured with a supply wire and
a frame connected green or bare copper grounding 
wire.
 DO NOT ground to a gas supply pipe. 
DO NOT connect to electrical power supply until 
appliance is permanently grounded. Connect the 
ground wire before turning on the power.
Important Notes to the Installer
1.  Read all instructions contained in these installation
instructions before installing the cooktop.
2.  Remove all packing material before connecting the
electrical supply to the cooktop.
3.  observe all governing codes and ordinances.
4.  Be sure to leave these instructions with the
consumer.
5.  only certain cooktop models may be installed over
certain built-in electric oven models. Approved
cooktops and built-in ovens are listed by the MFG ID
number and product code.
Important Note to the Consumer
Keep these instructions with your Use and Care Guide
for future reference.
IMPORTANT SAFETY 
INSTRUCTIONS
  Be sure your cooktop is installed and grounded 
properly by a qualified installer or service 
technician.
This cooktop must be electrically grounded in 
accordance with local codes or, in their absence, 
with the National Electrical Code ANSI/NFPA No. 
70—latest edition in the United States, or with 
CSA Standard C22.1, Canadian Electric Code, 
Part 1, in Canada.
WARNING
 The electrical power to the cooktop 
must be shut off while line connections are being 
made. Failure to do so could result in serious 
injury or death.
Provide Electrical Connection
Install the junction box under the cabinet and run
120/240 or 120/208 Volt, AC wire from the main circuit
panel. notE: Do not connect the wire to the circuit
panel at this time.
Electrical Requirements
Observe all governing codes and local ordinances.
1.  A 3-wire or 4-wire single phase 120/240 or
120/208 Volt, 60 Hz AC only electrical supply is
required on a separate circuit fused on both sides 
of the line (time-delay fuse or circuit breaker is
recommended). Do not fuse neutral.
2.  A circuit breaker or fuse rated at 50 Amp is
recommended (40 Amp minimum).
NOTE: Wire sizes and connections must conform with
the fuse size and rating of the appliance in accordance
with the national Electrical Code AnSI/nFPA no.
70–latest edition and local codes and ordinances.