Amana PTC093G25CXXX 规格说明表单

下载
页码 8
SS-DPTAC www.amana-ptac.com
 7
www.amana-ptac.com SS-DPTAC
P
roduCT
 s
PeCifiCATions
P
roduCT
 s
PeCifiCATions
P
roduCT
 s
PeCifiCATions
:  PTH m
odels
 — r
everse
-C
yCle
 H
eATing
 P
erformAnCe
Notes:
¹  All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit (PTPWHWK4).
²  Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; however, local codes should apply.
³  Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts. 
Minimum voltage on 265-volt models is 238.5 volts; maximum is 291.5 volts.
⁴  Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style time-delay 
fuses (included and factory-installed on all Amana® brand 265-volt chassis). See heater performance for total MCA.
⁵  Heating capacity and efficiency based on unit operation without condensate pump; unit automatically switches to electric heat  
at approximately 24°F outdoor ambient.
⁶  Total watts for 12,000 and 15,000 BTU/h models; subtract 70 watts for PT07/09*E**A*
⁷  Specify two-digit heater kW size to complete model number.
⁸  Total amps for 12,000 and 15,000 BTU/h models; subtract 0.2 amps for PT07/09*E*A*.
⁹  R-410A refrigerant used in all systems.
¹⁰  All units meet or exceed ASHRAE 90.1 standards.
¹¹  All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
¹²  Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only.
230/208 V
olts
Heating Capacity ¹
PTH  
073E**AXXX
PTH  
093E**AXXX
PTH  
123E**AXXX
PTH  
153E**AXXX
Voltage ¹
,
 ³
230 / 208
230 / 208
230 / 208
230 / 208
BTU/h
 
6,800 / 6,800
8,300 / 8,100
10,900 / 10,500
13,500 / 13,300
Amps
 
¹²
3.5 / 3.5
4.1 / 4.1
5.6 / 5.6
7.0 / 7.0
Watts
 
¹²
605 / 605
735 / 720
1040 /1020
1365 / 1345
COP
5
3.3 / 3.3
3.3 / 3.3
3.1 / 3.1
2.9 / 2.9
CFM (Dry)
310
310
310
360
265/277 V
olts
Heating Capacity ¹
PTH  
074E**AXXX
PTH  
094E**AXXX
PTH  
124E**AXXX
PTH  
154E**AXXX
Voltage ¹
,
 ³
265
265
265
265
BTU/h
 
6,800
8,200
11,000
13,500
Amps
 
¹²
3.0
3.6
4.8
6.0
Watts
 
¹²
585
730
1040
1365
COP
 
3.4
3.3
3.1
2.9
CFM (Dry)
310
310
310
360
COP = Coefficiency of Performance; per ARI test procedures, units are rated for capacities and efficiencies.