Whirlpool GI15NDXZ 业主指南

下载
页码 64
5
The pressure of the water supply coming out of a reverse 
osmosis system going to the water inlet valve of the ice 
maker needs to be between 30 and 120 psi (207 and 
827 kPa).
If a reverse osmosis water filtration system is connected to your 
cold water supply, the water pressure to the reverse osmosis 
system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
NOTE: The reverse osmosis system must provide 1 gal. (3.8 L) of 
water per hour to the ice maker for proper ice maker operation. If 
a reverse osmosis system is desired, only a whole-house 
capacity reverse osmosis system, capable of maintaining the 
steady water supply required by the ice maker, is recommended. 
Faucet capacity reverse osmosis systems are not able to 
maintain the steady water supply required by the ice maker. 
If the water pressure to the reverse osmosis system is less than 
40 to 60 psi (276 to 414 kPa):
Check to see whether the sediment filter in the reverse 
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill 
after heavy usage.
If you have questions about your water pressure, call a licensed, 
qualified plumber.
Vacation or Extended Time 
Without Use
When you will not be using the ice maker for an extended 
period of time, turn off the water and power supply to the ice 
maker.
Check that the water supply lines are insulated against 
freezing conditions. Ice formations in the supply lines can 
increase water pressure and cause damage to your ice maker 
or home. Damage from freezing is not covered by the 
warranty.
Connect Water Supply
Read all directions before you begin.
IMPORTANT:
Plumbing shall be installed in accordance with the 
International Plumbing Code and any local codes and 
ordinances.
Use copper tubing or Whirlpool supply line, Part Number 
8212547RP, and check for leaks.
Install tubing only in areas where temperatures will remain 
above freezing.
Tools Needed
Gather the required tools and parts before starting installation: 
Flat-blade screwdriver
⁷⁄₁₆" and ¹⁄₂" open-end wrenches or two adjustable wrenches
¹⁄₄" nut driver
NOTE: Do not use a piercing-type or
 ³⁄₁₆" (4.76 mm) saddle valve 
which reduces water flow and clogs more easily.
Connecting the Water Line
1. Turn off main water supply. Turn on nearest faucet long 
enough to clear line of water.
2. Using a 
¹⁄₂" copper supply line with a quarter-turn shutoff 
valve or the equivalent, connect the ice maker as shown. 
NOTE: To allow sufficient water flow to the ice maker a 
minimum 
¹⁄₂" diameter home supply line is recommended.  
3. Now you are ready to connect the copper tubing. Use 
¹⁄₄" 
(6.35 mm) OD soft copper tubing for the cold water supply.
Ensure that you have the proper length needed for the 
job. Be sure both ends of the copper tubing are cut 
square.
Slip compression sleeve and compression nut on copper 
tubing as shown. Insert end of tubing into outlet end 
squarely as far as it will go. Screw compression nut onto 
outlet end with adjustable wrench. Do not overtighten.
4. Place the free end of the tubing into a container or sink, and 
turn on main water supply and flush out tubing until water is 
clear. Turn off shutoff valve on the water pipe.
IMPORTANT: Always drain the water line before making the 
final connection to the inlet of the water valve to avoid 
possible water valve malfunction.
5. Bend the copper tubing to meet the water line inlet which is 
located on the back of the ice maker cabinet as shown. 
Leave a coil of copper tubing to allow the ice maker to be 
pulled out of the cabinet or away from the wall for service.
Rear View
A. Bulb
B. Nut 
A. Compression sleeve
B. Compression nut
C. Copper tubing
A. Copper tubing
B. Water supply tube clamp
C. Inlet water tube clamp and 
supply line connector
A
B
B
C
A
A
C
B