Maytag MDE17PRAYW 安装指导

下载
页码 56
15
1.  Remove red cap from gas pipe on back of dryer.
2.   Connect gas supply to dryer. Use a pipe thread compound 
approved for the type of gas supplied. If flexible metal 
tubing is used, be certain there are no kinks.
If necessary for service, open the toe panel. Use a putty 
knife to press on the toe panel locks located near the two 
ends of the toe panel. Pull downward on the toe panel to 
open. Toe panel is hinged at the bottom.
3.   Open the shut-off valve in the gas supply line and make sure 
the dryer has its own gas supply opened.
4.   Test all connections by brushing on an approved 
noncorrosive leak-detection solution. Bubbles will show  
a leak. Correct any leaks found.
Make Gas Connection
GAS SUPPLY CONNECTION
The outside end of main vent should have a sweep elbow 
directed downward. 
If main vent travels vertically through the roof, rather than 
through wall, install a 180° sweep elbow on end of vent at least 
2 ft. (610 mm) above surface of roof. 
The opening in wall or roof shall have a diameter 1⁄2" (13 mm) 
larger than vent diameter. Vent should be centered in opening.
Do not install screening over end of vent for best performance.
12" min.
(305 mm)*
A main vent can be used for venting a group of dryers. The 
main vent should be sized to remove 5663 l/min. (200 CFM)  
of air per dryer. Large-capacity lint screens of proper design 
may be used in main vent if checked and cleaned frequently. 
The room where the dryers are located should have make-up 
air equal to or greater than CFM of all the dryers in the room.
Back-draft Damper Kit, Part No. 3391910, is available from  
your distributor and should be installed in the vent of each 
dryer to keep exhausted air from returning into dryers and to 
keep exhaust in balance within main vent. Unobstructed return 
air openings are required.
Each vent should enter the main vent at an angle pointing in 
the direction of the airflow. Vents entering from the opposite 
side should be staggered to reduce the exhausted air from 
interfering with the other vents.
The maximum angle of each vent entering the main vent 
should be no more than 30°.
Keep air openings free of dry cleaning fluid fumes. Fumes 
create acids which, when drawn through the dryer heating 
units, can damage dryers and items being dried.
A clean-out cover should be located on the main vent for 
periodic cleaning of the vent system.
If an Exhaust Hood Cannot be Used
Multiple Dryer Venting
DRYER VENTING REQUIREMENTS
24" min.
(610 mm)
* Minimum clearance above 
any accumulation of snow, 
ice, or debris such as leaves
30˚ max.
air flow
air flow