INSTALLATION REQUIREMENTS
NOTE
Drain hose attached to the washer can reach a 74 in. 
(188 cm) high standpipe. For higher standpipe, use 
hose P/N 137098000, available from an authorized 
parts distributor. 
NOTE
GFI (Ground Fault Interrupter) receptacle is not 
required.
NOTE
Because of potentially inconsistent voltage capabilities, 
the use of this washer with power created by gas 
powered generators, solar powered generators, wind 
powered generators or any other generator other than 
the local utility company is not recommended.
CIRCUIT -  Individual, properly polarized and grounded 
15 amp. branch circuit fused with 15 amp. time delay 
fuse or circuit breaker.
POWER SUPPLY - 2 wire, with ground, 120 volt single 
phase, 60 Hz, Alternating Current.
OUTLET RECEPTACLE - Properly grounded 3-prong 
receptacle to be located so the power supply cord is 
accessible when the washer is in an installed position.
Grounding type
Grounding type
wa
wall receptacl
ll receptacle
Po
Power cord with
wer cord with
3-prong 
3-prong  gr
grounded plug
ounded plug
Do not,
Do not, under
under
an
any cir
y circumstances,
cumstances,
cut,
cut, remo
remove
ve,
or b
or bypass th
ypass the
gr
grounding pr
ounding prong.
ong.
96”
(244cm)
max.
24”
(61cm)
min.
Drain system requirements
  1  Drain capable of eliminating 17 gals (64.3 L) per 
minute.
  2  A standpipe diameter of 1-1/4 in. (3.18 cm) 
minimum.
  3  The standpipe height above the fl oor should be:
Minimum height:   24 in. (61 cm)
Maximum height:  96 in. (244 cm)
Water supply requirements
Hot and cold water faucets MUST be installed within hose 
length of your washer’s water inlet. The faucets MUST 
be 3/4 inch (1.9 cm) with threading for laundry hose 
connection. Water pressure MUST be between 30 and 
120 psi. Pressure difference between hot and cold cannot 
be more than 10 psi. Your water department can advise 
you of your water pressure.
  1  The washer MUST be grounded. In the event of 
malfunction or breakdown, grounding will reduce 
the risk of electrical shock by a path of least 
resistance for electrical current.
  2  Since your washer is equipped with a power supply 
cord having an equipment-grounding conductor 
and a grounding plug, the plug MUST be plugged 
into an appropriate, copper wired receptacle that is 
properly installed and grounded in accordance with 
all local codes and ordinances or in the absence 
of local codes, with the National Electrical Codes, 
ANSI/NFPA 70 (latest edition). If in doubt, call a 
licensed electrician. DO NOT cut off or alter the 
grounding prong on the power supply cord. In 
situations where a two-slot receptacle is present, 
it is the owner’s responsibility to have a licensed 
electrician replace it with a properly grounded three 
prong grounding type receptacle.
Ground requirements
Electrical system requirements
WARNING
ELECTRICAL SHOCK HAZARD
Improper connection of the equipment grounding 
conductor can result in a risk of electrical shock. Check 
with a licensed electrician if you are in doubt as to 
whether the appliance is properly grounded.