Your safety and the safety of others are very important. 
This safety Alert  symbol warns you from  potential  hazards  that  can  kill  or  hurt  you  and others.
All  safety  messages  will  follow  the  safety  alert symbol with the word “WARNING” or “CAUTION”. These words mean:
WARNING 
Indicates  a  hazard  which,  if  not  avoided,  can  result  in  severe  personal  injury  or  death  and  damage  to
product or other property.
CAUTION 
    
Indicates a hazard which, if not avoided, can result in personal injury and  damage to product or other property.
NOTICE
 
Indicates property damage can occur if instructions are not followed.
Model Plug
Type
WS08, WS10, WS12      
NEMA No. 5-15P   125 V-15 AMP
NEMA No. 6-15P    250V-15 AMP
WS10, WS12, WS15 
WE10, WE12, WE15, 
WY09, WY12
NEMA No. 6-20P    250V-20 AMP
Electrical Data
Electrical Shock Hazard
WARNING
Make  sure  your  electrical  receptacle  has  the  same 
configuration  as  your  air  conditioner’s  plug.  If 
different, consult a Licensed Electrician. 
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong. 
Always plug into a grounded 3 prong outlet. 
Failure to follow these instructions can result in death, 
fire, or electrical shock. 
Circuit Rating, 
Breaker or Time 
Delay Fuse 
Safety Precautions
Never use an extension cord
Your  Friedrich  room  air  conditioner  is  equipped  with  a  three-
prong (grounded) plug for your protection against shock hazards 
and should be plugged directly into a properly grounded three-
prong  receptacle.  If  you  have  a  two-prong  receptacle  you  will 
need to have the circuit replaced by a certified electrician with a 
grounded  circuit  that  meets  all  national  and  local  codes  and 
ordinances.  Under  no  circumstances  should  you  remove  the 
ground prong from the plug. You must use the three-prong plug 
furnished with the air conditioner.
NEVER CUT OR REMOVE THE GROUNDING PRONG FROM THE 
PLUG.
Power cord information
All  Friedrich  room  air  conditioners  are  shipped  from  the 
factory with a Leakage Current Detection Interrupter (LCDI) 
equipped  power  cord.  The  LCDI  device  meets  the  UL  and 
NEC  requirements  for  cord  connected  air  conditioners 
effective August 2004.
To test your power supply cord:
1.
Plug power supply cord into a grounded 3 prong outlet.
2.
Press 
RESET (See Figure A).
3.
Press 
TEST (listen for click; Reset button trips and pops out).
4.
Press and release 
RESET (listen for click; Reset button
latches and remains in). The power supply cord is ready for
operation.
NOTE: LCDI device is not intended to be used as a switch.
Once plugged in the unit will operate normally without the 
need to reset the LCDI device. 
If the device fails to trip when tested or if the power supply 
cord is damaged it must be replaced with a new supply cord 
from  the  manufacturer.  We  recommend  you  contact  our 
Technical  Assistance  Line  at  (800)  541-6645  ext.  845.  To 
expedite service, please have your model  and serial number 
available.
3
TEST
RESET
WARNING
TEST BEFORE EACH USE
1.
 PRESS RESET BUTTON
2.
 PLUG LDCI INTO POWER
RECEPTACLE
3.
 PRESS TEST BUTTON,
RESET BUTTON SHOULD
POP UP
4.
 PRESS TEST BUTTON,
FOR USE,
DO NOT USE IF ABOVE TEST
FAILS WHEN GREEN LIGHT 
IS ON
RESET
TEST
Figure A
NOTE: 
Your LCDI device will resemble one of these 
illustrations.
We have provided important safety messages in this manual and on your appliance. Always read and obey all safety messages. All safety messages will 
tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what will happen if the instructions are not followed.