Viking TVDR4806BGB 安装指导

下载
页码 24
14
1
1
5
6
Push supply cord toward terminal block to relieve 
strain, reattach supply cord strain relief bracket over 
supply cord.
Reattach access door.
Electrical Connection
3-Wire (con’t)
Electrical Connection
4-Wire
WARNING
 ELECTRICAL SHOCK HAZARD
To avoid risk of electrical shock, personal injury 
or death; verify your appliance has been properly 
grounded in accordance with local codes or in 
absence of codes, with the National Electrical Code (NEC) ANSI/
NFPA-70 – latest edition.
WARNING
 ELECTRICAL SHOCK HAZARD
To avoid risk or electrical shock, personal injury 
or death; grounding product to the frame of the 
unit may or may not be permitted through your 
local codes. If ground to the frame is not permitted then a 4 
conductor power cord must be used.
See Electrical Requirements information.  Where local codes do not permit grounding through neutral, use a 4-wire power supply 
cord. The cord or conduit must be secured to the range with the strain relief bracket.  The electrical connection is made at the 
terminal block, which is located behind the access door on the back of the range.
1
2
Remove access door.
Remove supply cord strain relief 
bracket and three supply cord mounting screws
on terminal block.