Frigidaire FFGC3610Q 安装指导

下载
页码 28
GAS COOKTOP INSTALLATION INSTRUCTIONS
(For 30" & 36" Models)
7
The supply line must be equipped with an approved 
manual shutoff valve. This valve should be located in the 
same room as the cooktop and should be in a location 
that allows ease of opening and closing. Do not block 
access to the shutoff valve. The valve is for turning on or 
shutting off gas to the appliance.
5. Install Pressure Regulator
Install the pressure regulator with the arrow on the 
regulator pointing up toward the unit in a position 
where you can reach the access cap.
 Do not make the connection too tight. 
The regulator is die cast. Overtightening may crack the 
regulator resulting in a gas leak and possible fi re or 
explosion.
Figure 8
Shutoff Valve -
Open position
to appliance
to gas suppl
y line
All connections must be wrench-tightened
Figure 7
Flare
Union
Flare
Union
GAS FLOW
Manual
Shutoff
Valve
Pressure
Regulator
On
Off
Flexible
Connector
Access
Cap
Nipple
Nipple
Assemble the fl exible connector from the gas supply pipe 
to the pressure regulator in the following order:
1.  manual shutoff valve
2.  1/2" (1.3 cm) nipple
3.  1/2" (1.3 cm) fl are union adapter
4. fl exible connector
5.  1/2" (1.3 cm) fl are union adapter
6.  1/2" (1.3 cm) nipple
7. pressure regulator
Use pipe-joint compound made for use with Natural and 
LP/Propane gas to seal all gas connections. If fl exible 
connectors are used, be certain connectors are not 
kinked.
Once regulator is in place, open the shutoff valve in the 
gas supply line. Wait a few minutes for gas to move 
through the gas line.
Check for leaks. After connecting the cooktop to the 
gas supply, check the system for leaks with a manometer. 
If a manometer is not available, turn on the gas supply 
and use a liquid leak detector (or soap and water) at all 
joints and connections to check for leaks.
 Do not use a fl ame to check for leaks from 
gas connections. Checking for leaks with a fl ame may 
result in a fi re or explosion.
Tighten all connections if necessary to prevent gas 
leakage in the cooktop or supply line.
Check alignment of control knob valves after 
connecting the cooktop to the gas supply to be sure the 
cooktop manifold pipe has not moved. A misalignment 
could cause the valve stems to rub on the control panel, 
resulting in a gas leak at the valve.
Disconnect this cooktop and its individual manual 
shutoff valve
 from the gas supply piping system during 
any pressure testing of that system at test pressures 
greater than 1/2 psig (3.5 kPa or 14"water column).
Isolate the cooktop from the gas supply piping 
system
 by closing its individual manual shutoff valve 
during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 1/2 psig 
(3.5 kPa or 14" water column).