Viking RVDR33015BBK 安装指导

下载
页码 14
14
15
2
1
1
Remove access door.
Electrical Connection (3-wire)
Note: If you have a 4-wire connection, see following section for
4-wire connection instructions.
Use a 3-wire power supply cord kit rated for
40 amps – 125/250 volts with closed loop
terminals and marked for use with ranges. 
Where local codes do not permit grounding
through neutral, use a 4-wire power supply
cord. The cord or conduit must be secured
to the range with the strain relief bracket.
The electrical connection is made at the
terminal block, which is located behind the
access door on the back of the range.
3
2
1
2
Remove supply cord strain relief 
bracket and three supply cord mounting screws
on terminal block.
WARNING
ELECTRICAL SHOCK
HAZARD
To avoid risk or electrical
shock, personal injury or death;
grounding product to the frame of the unit
may or may not be permitted through
your local codes. If ground to the frame is
not permitted then a 4-conductor power
cord must be used.
WARNING
ELECTRICAL SHOCK
HAZARD
To avoid risk of electrical shock,
personal injury or death; verify
your appliance has been properly
grounded in accordance with local codes
or in absence of codes, with the National
Electrical Code (NEC) ANSI/NFPA-70 –
latest edition.
Leg Installation
3
Feed supply cord up through hole in bottom 
of range back.
1
1
1
2
3
2
2
Legs are packed in the cardboard top pack. 
Note: Legs should be installed near to where
appliance is to be used, as they are 
not secure for long transit.
Note: It is strongly recommended
that a pallet or lift jack be used rather than tilting.
Raise unit about a foot. Unscrew temporary legs 
from couplings
4
Lower range gently to keep any undue strain from
legs and internal mounting hardware.
3
Screw legs into couplings on all 
four corners.