Area
Description
Free Standing/Alcove In-
stallation
Closet Installation
A*
Dryer sides and rear clearance
0 in. [0 mm]
0 in. [0 mm]
B
Dryer top clearance
12 in. [305 mm]
12 in. [305 mm]
C
Dryer front clearance
Not Applicable
2 in. [51 mm]
D
Exhaust duct clearance to com-
bustible material
2 in. [51 mm]
2 in. [51 mm]
E
Weather hood to ground clear-
ance
12 in. [305 mm]
12 in. [305 mm]
F
Distance from floor or ceiling
to air opening edge
Not Applicable
3 in. [76 mm]
G
Area of centered air openings
in closet door. Louvered door
with equivalent air openings is
acceptable. (Minimum clearan-
ces are shown.)
Not Applicable
40 sq. in./open [1016 sq. mm/
open]
H
For new installations, locate
top of wall vent 42 inches
[1067 mm] above floor to make
venting easier to connect.
42 in. [1067 mm]
42 in. [1067 mm]
*
Rear clearance is minimum. 2 inches [51 mm] is recommended for utility connection. 6 inches
[152 mm] is recommended when venting through rear of unit.
Table 1
IMPORTANT: In mobile home installations, gas dryers
MUST be permanently attached to the floor at the time
of installation. Order No. 526P3 Hold Down Kit (availa-
ble at extra cost) for a manufactured (mobile) home in-
stallation. Follow the instructions supplied with the kit.
Installation of unit must conform to the Manufactured Home
Construction and Safety Standards, Title 24 CF4, Part 32-80 or
Standard CAN/CSA-Z240 MH.
 Connect Dryer Exhaust System
WARNING
To reduce the risk of fire and combustion gas accu-
mulation the dryer MUST be exhausted to the out-
doors.
W604
WARNING
To reduce the risk of fire and the accumulation of
combustion gases, DO NOT exhaust dryer air into a
window well, gas vent, chimney or enclosed, unven-
tilated area, such as an attic, wall, ceiling, crawl
space under a building or concealed space of a
building.
W045
Installation
  Part No. 514319R1
©
 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT