INSTALLATION: 
STEP 2: VENTILATION REQUIREMENTS 
HOOD PLACEMENT: 
WARNING: DO NOT obstruct the flow of combustion and ventilation air to the unit.
 
For best smoke elimination, the lower edge of the hood should be installed  a minimum of 30" to a maximum of 36" above 
the range cooking surface. 
CAPITAL Hood blower speeds are variable to reduce n o i s e   a n d   l o s s   o f   h e a t e d   o r   a i r - c o n d i t i o n e d   household  air  when 
maximum ventilation is not  required. Normally the maximum blower speed i s only required when using the grill section. 
Any openings in the wall behind the range and in the floor under the range must be sealed. 
W h e n   t h e r e   i s   l e s s   t h a n   1 2 "   h o r i z o n t a l   clearance  between  combustible  material  D  and  the  back  edge  of 
the  range  above  the  cooking  s u r f a c e ,   a   C a p i t a l   L o w  B a c k   o r   H i g h   S h e l f   bac k   guard  m ust   be  ins t alled  
(s ee  Fig.   2A ).   W hen  clearance  to  combustible  material  D  is  over  12",  a  Capital  Island  Trim  may  be  used 
(See Fig. 2B). Figures 2A and 2B indicate the  space required for each type of back guard. 
Always keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
 
CAUTION: Ventilation hoods and blowers are  d e s i g n e d   f o r   u s e   w i th   s i n g l e   w a l l   d u c ti n g .   However, some local 
building codes or inspectors may require double wall ducting. Consult local building codes and/or local agencies, 
before starting, to assure that hood and duct installation will meet local requirements. 
SELECT HOOD AND BLOWER MODELS:
 
It is strongly recommended that a suitable CAPITAL exhaust hood be installed above the range. Downdraft ventilation 
should NOT be used. The table below indicates the PRECISION Series Hoods, by model number, that are 
recommended for use with all ranges. 
VENTILATION UNIT
 
STANDARD COUNTER
 
INSTALLATION
 
RECOMMENDATIONS
 
HOOD
 
(24" DEEP X UNIT WIDTH)
 
 
 
BLOWER CFM's
 
 
SIZE
 
SHIPPING WEIGHT
 
60" RANGE = 1200 CFM
 
 
30"
 
400
 
48" RANGE =1200 CFM
 
 
36"
 
450
 
36" RANGE =1200 CFM
 
 
48"
 
630
 
30" RANGE = 600 CFM
 
 
60"
 
800
 
 
For wall installations, the hood wi dth must, at a minimum, equal the width of the range's cooking surface. Where space 
permits, a hood larger in  width than the cooking surface may be desirable for improved ventilation performance.
 
WARNING: DO NOT lift the range by the oven door handles, Do not remove the griddle and grill sections!
 
 
Lift the range from the skid with a soft wheel dolly. 
 
Support the range uniformly across the bottom 
 
To remove door, open the door completely, close the hinge latches and release the door. Remove door by lifting and 
pulling from the sides. 
 
Make sure gas and electric connections are made, anti-tip device is installed, and the back guard installed prior to placing 
the range in position. 
 
Measure the height of the counter top and adjust the range height to match countertop height by adjusting front and rear 
leveling feet. 
 
Slide the range in place and ensure that the range is level. 
 
Reinstall the kick plate, top grates, oven door(s), drip pan tray(s), and make sure burner caps are seated firmly located 
into position.