Convert from Natural Gas to LP Gas
1. Turn manual shutoff valve to the closed position.
2. Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
3. Determine the type of regulator you have:
Style 1: The cap has a slot and “NAT” printed on it.
Remove access cap by using a flat-blade screwdriver or coin, 
turning the access cap counterclockwise.
The gas pressure regulator has 2 settings that are stamped 
on either side of the cap. Turn the cap and reinstall into 
regulator with the stamp “LP” visible from the outside of the 
regulator.
Style 2: The cap does not have a slot and requires a wrench 
to be removed.
Remove the access cap by using a wrench, turning the 
access cap counterclockwise.
Remove spring retainer from the cap by pushing against the 
flat side of the spring retainer. Look at the spring retainer to 
locate the “NAT” or “LP” position. Turn over the spring 
retainer so the “LP” is showing on the bottom. Snap the 
spring retainer back into the cap. Reinstall the cap onto the 
regulator.
A. To cooktop
B. Shutoff valve (closed position)
C. Gas supply line
WARNING
This conversion kit shall be installed by a 
qualified service agency in accordance 
with the manufacturer's instructions and 
all applicable codes and requirements of 
the authority having jurisdiction. If the 
information in these instructions is not 
followed exactly, a fire, explosion or 
production of carbon monoxide may 
result causing property damage, personal 
injury or loss of life. The qualified service 
agency is responsible for the proper 
installation of this kit. The installation is 
not proper and complete until the 
operation of the converted appliance is 
checked as specified in the 
manufacturer's instructions supplied with 
this kit.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
C
A. Access cap
B. Rear of cooktop
C. Gas pressure regulator
D. Gas flow
A. Access cap
B. Gasket
C. Gas pressure regulator
D. LP position
E. NAT position
A
B
C
D
A
B
C
D
E