Whirlpool WCG75US0DS 数据表

下载
页码 20
3
Tools and Parts
Gather the required tools and parts necessary for correct LP gas 
conversion.
Tools needed
Flat-blade screwdriver
³⁄₃₂" (#0 [2.0 mm]) flat-blade screwdriver (screwdriver shaft 
must be a minimum of 2" [5.1 cm] long)
Adjustable wrench
7.0 mm nut driver
7.0 mm wrench
T10 Torx
®†
 adapter
Parts needed
For models KCGS550ESS, KCGS556ESS, KCGS950ESS and 
KCGS956ESS use the following parts:
LP orifice package (W10676662)
Conversion instructions (W10597146A)
For all other models use the following parts:
LP orifice package (W10676661)
Conversion instructions (W10597146A)
High Altitude Conversion
To convert the cooktop for elevations above 6,560 ft (1999.5 m), 
order a High Altitude Conversion Kit.
For models KCGS550ESS, KCGS556ESS, KCGS950ESS and 
KCGS956ESS use the following parts:
Part Number W10679116 - LP high altitude
Part Number W10679118 - Natural gas high altitude
For all other models use the following parts:
Part Number W10679114 - LP high altitude
Part Number W10679113 - Natural gas high altitude
To order, see the “Assistance or Service” section of the User Guide.
IMPORTANT: Gas conversions from Natural gas to LP gas must 
be done by a qualified installer. Before proceeding with 
conversion, shut off the gas supply to the cooktop prior to 
disconnecting the electrical power.
Convert from Natural Gas to LP Gas
1. Turn manual shutoff valve to the closed position.
2. Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
3. Determine the type of regulator you have:
Style 1: The cap has a slot and “NAT” printed on it.
Remove access cap by using a flat-blade screwdriver or coin, 
turning the access cap counterclockwise.
†®TORX is a registered trademark of Acument Intellectual Properties, LLC.
WARNING
This conversion kit shall be installed by a 
qualified service agency in accordance 
with the manufacturer's instructions and 
all applicable codes and requirements of 
the authority having jurisdiction. If the 
information in these instructions is not 
followed exactly, a fire, explosion or 
production of carbon monoxide may 
result causing property damage, personal 
injury or loss of life. The qualified service 
agency is responsible for the proper 
installation of this kit. The installation is 
not proper and complete until the 
operation of the converted appliance is 
checked as specified in the 
manufacturer's instructions supplied with 
this kit.
A. To cooktop
B. Shutoff valve (closed position)
C. Gas supply line
A. Access cap
B. Rear of cooktop
C. Gas pressure regulator
D. Gas flow
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
C
A
B
C
D