   Wolf Customer Care 800.222.7820
SPECIFICATIONS
Electrical
Installation must be electrically grounded in accordance 
with local codes or, in the absence of local codes, with the 
National Electrical Code, ANSI/NFPA 70.
Locate the electrical supply as shown in the illustrations on 
pages 5–6. A separate circuit, servicing only this appliance 
is required. A ground fault circuit interrupter (GFCI) is not 
recommended and may cause interruption of operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
grounded, 120 VAC, 60 Hz
Service
15 amp dedicated circuit
Receptacle
3-prong grounding-type
Power Cord
6'
 (1.8 m)
Installation Requirements
The coffee system can be installed in a standard or flush 
inset application. A minimum base support of 100 lbs
 
(45 kg)
 is required. The sides of the cabinetry opening must 
be adequate to support installation of the mounting slides.
Finish the edges of the opening. They may be visible when 
the unit is slid forward.
The unit has face trim on the top, bottom and both sides 
that will overlap stiles and rails. Refer to the chart below for 
trim overlaps. For flush inset installations, a minimum 
1
/
8
"
 (3)
 
reveal is required on all four sides. To ensure consistent 
1
/
8
"
 
(3)
 reveals, each corner of the opening must be exactly 90°.
The Wolf coffee system is designed and agency approved 
for installation with Wolf cooktops, built-in ovens, micro-
waves and warming drawers only.
TRIM OVERLAP
OVERLAP
Top
3
/
16
"
 (5)
Bottom
0"
 (0)
Sides
11
/
16
"
 (18)