 Cabinet   
30"
  A – Overlap of oven at top of cutout 
1"
  B – Overlap of oven over side of edges of cutout 
11/16"
  C – Overlap of oven at bottom of cutout 
1-1/4"
Oven 
  D – Overall depth with handle  
27"
          Overall depth without handle  
23-1/2"
   E – Overall height with trim 
44"
  F  – Overall width 
29-3/4"
21" minimum
door opening
allowance
Conduit 
 
  48" 
CL
Suitable
bracing
to support
runners
2 x 4 or
equivalent runners
level with bottom of cutout
and flush with sides of cutout
or solid bottom floor.
B
30 ''
A
C
Cutout width
28-1/2" MIN.
  28-5/8" MAX.
Recommended
minimum
cutout location
from the floor  
21-5/8"
Cutout height
42-1/4" MAX.
42-3/16 MIN.
CT9800
PT9800
PT7800
JT3800
21"
E
F
D
ATTENTION INSTALLER:
 
All electric wall ovens must be hard-wired (direct-wired)
into an approved junction box. A plug and receptacle is NOT permitted on these products.
NOTE: If the cabinet does not have a solid bottom,
two braces or runners must be installed to support
the weight of the oven. For single ovens, the runners
and braces must support 200 lbs (91 kg). For double
ovens, the runners and braces must support 375 lbs.
(170 kg).
NOTE: If marks, blemishes or the cutout opening are
visible above the installed oven, it may be necessary
to add wood shims under the runners and front trim
until the marks or opening are covered.
NOTE: If the cabinet does not have a front frame
and the sides are less than 3/4" (1.9 cm) thick, shim
both sides equally to establish the cutout width.
9-1/2"
 MAX.
Right side only
28" MIN. to
bottom of
junction box 
Junction box
location
(Junction box
may be located
in adjacent
cabinet) 
PT7800DH 
GE Profile
 Series 30" Built-In Combination Convection Microwave/Convection Wall Oven
 
Dimensions and Installation Information (in inches)
Note: Cabinets installed adjacent to wall 
ovens must have an adhesion spec of at 
least a 194°F temperature rating.
Installation Information: Before installing, 
consult installation instructions packed with 
product for current dimensional data.
Door handle protrudes 3" from door face. 
Cabinets and drawers on adjacent 45° 
and 90° walls should be placed to avoid 
interference with the handle.
Electric wall ovens are not approved for 
installation with a plug and receptacle. 
They must be hard wired in accordance 
with installation instructions.
Note:
 These ovens are not approved for 
stackable or side-by-side installations.
KW Rating
240V
6.8
208V
5.1
Breaker Size
240V
30 Amps
208V
30 Amps