Viking VDSC5304BSS 安装指导

下载
页码 14
42” min.
 
(106.7 cm)
13” max.
 
(
33.0 cm)
6” min.
(15.2 cm)
18” min.
(45.7 cm
)
3/8”
 
(0.95 cm)
36” 
(
91.4 cm)
29-7/8”
(75.9 cm)
A
(opening width)
Clearance Dimensions 
(Wood/Composite Overlay)
11
Clearance Dimensions 
(Proximity to Cabinets)
10
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
30”
(76.2 cm)
6”
(15
.2 c
m)
Wood/Composite 
Overlay
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
24”
(61.0 cm)
or
27”
(38.6 cm)
Wood/Composite 
Overlay
0”
 
(
0 cm)
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)
Wall Installation
Island Installation
Note: Minimum clearance for back wall
is 0” with backguard or high-shelf.
CAUTION
Burn hazard.
To avoid risk of personal injury;
the use of cabinets for storage
above the appliance may result
in a potential burn hazard. Combustible
items may ignite, metallic items may
become hot and cause burns. If a cabinet
storage is to be provided the risk can be
reduced by installing a rangehood that
projects horizontally a minimum 5” 
(12.7 cm) beyond the bottom of cabinets.
CAUTION
To prevent possible damage to cabinets
and cabinet finishes, use only materials
and finishes that will not discolor or
delaminate and will withstand temperatures
up to 194
°F (90°C). Heat and moisture
resistant adhesive must be used if the
product is to be installed in laminated
cabinetry. Check with your builder or
cabinet supplier to make sure that the
materials meet these requirements.
• This range may be installed directly 
adjacent to existing 36” (91.4 cm) high 
base cabinets.
IMPORTANT: The side trim MUST be
3/8” (.95 cm) above the adjacent base 
cabinet countertop. This can be 
accomplished by raising the unit using the 
adjustment spindles on the legs.
• The range CANNOT be installed directly 
adjacent to sidewalls, tall cabinets, tall 
appliances, or other side vertical surfaces 
above 36” (91.4 cm) high. There must be a
minimum of 6” (15.2 cm) side clearance 
from the range to such combustible 
surfaces above the 36” (91.4 cm) counter 
height.
• Within the 6” (15.2 cm) side clearance to 
combustible vertical surfaces above 36” 
(91.4 cm), the maximum wall cabinet 
depth must be 13” (33.0 cm) and wall 
cabinets within this 6” (15.2 cm) side 
clearance must be 18” (45.7 cm) above the
36” (91.4 cm) high countertop.
• Wall cabinets above the range must be a 
minimum of 42” (106.7 cm) above the 
range cooking surface for the full width of 
the range. This minimum height 
requirement does not apply if a range 
hood is installed over the cooking surface.
The bottom of a standard hood
should be 30” (76.2 cm) min. to
36” (91.4 cm) max. above the
countertop. This would typically
result in the bottom of the hood
being 66” (167.6 cm) to 72”
(182.9 cm) above the floor. Refer
to the range hood installation
instructions for additional
information. These dimensions
provide for safe and efficient
operation of the hood.
Range
Width
“A”
Dimension
30”
30” (76.2 cm)
36”
36” (91.4 cm)
48”
48” (121.9 cm)
60”
60-1/8” (152.7 cm)
Note: If a range hood is installed, wall cabinets above the
range have a different minimum clearance height.
Note: Minimum clearance for
back wall is 0” with backguard
or high-shelf.
Important: This range comes standard
with an Island Trim. There must be a
minimum of 6” (15.2 cm) clearance from
rear of range to a combustible wall.
Clearances from non-combustible
materials are not part of the ANSI Z21.1
scope and are not certified by CSA.
Clearances to non-combustible materials
must be approved by the authority having
jurisdiction.